Detailed Information

Cited 12 time in webofscience Cited 13 time in scopus
Metadata Downloads

Artificial Intelligence-Based Solution in Personalized Computer-Aided Arthroscopy of Shoulder Prostheses

Full metadata record
DC Field Value Language
dc.contributor.authorSultan, Haseeb-
dc.contributor.authorOwais, Muhammad-
dc.contributor.authorChoi, Jiho-
dc.contributor.authorMahmood, Tahir-
dc.contributor.authorHaider, Adnan-
dc.contributor.authorUllah, Nadeem-
dc.contributor.authorPark, Kang Ryoung-
dc.date.accessioned2023-04-27T13:41:04Z-
dc.date.available2023-04-27T13:41:04Z-
dc.date.issued2022-01-
dc.identifier.issn2075-4426-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/3788-
dc.description.abstractBackground: Early recognition of prostheses before reoperation can reduce perioperative morbidity and mortality. Because of the intricacy of the shoulder biomechanics, accurate classification of implant models before surgery is fundamental for planning the correct medical procedure and setting apparatus for personalized medicine. Expert surgeons usually use X-ray images of prostheses to set the patient-specific apparatus. However, this subjective method is time-consuming and prone to errors. Method: As an alternative, artificial intelligence has played a vital role in orthopedic surgery and clinical decision-making for accurate prosthesis placement. In this study, three different deep learning-based frameworks are proposed to identify different types of shoulder implants in X-ray scans. We mainly propose an efficient ensemble network called the Inception Mobile Fully-Connected Convolutional Network (IMFC-Net), which is comprised of our two designed convolutional neural networks and a classifier. To evaluate the performance of the IMFC-Net and state-of-the-art models, experiments were performed with a public data set of 597 de-identified patients (597 shoulder implants). Moreover, to demonstrate the generalizability of IMFC-Net, experiments were performed with two augmentation techniques and without augmentation, in which our model ranked first, with a considerable difference from the comparison models. A gradient-weighted class activation map technique was also used to find distinct implant characteristics needed for IMFC-Net classification decisions. Results: The results confirmed that the proposed IMFC-Net model yielded an average accuracy of 89.09%, a precision rate of 89.54%, a recall rate of 86.57%, and an F1.score of 87.94%, which were higher than those of the comparison models. Conclusion: The proposed model is efficient and can minimize the revision complexities of implants.-
dc.format.extent18-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleArtificial Intelligence-Based Solution in Personalized Computer-Aided Arthroscopy of Shoulder Prostheses-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/jpm12010109-
dc.identifier.scopusid2-s2.0-85123211419-
dc.identifier.wosid000747837400001-
dc.identifier.bibliographicCitationJournal of Personalized Medicine, v.12, no.1, pp 1 - 18-
dc.citation.titleJournal of Personalized Medicine-
dc.citation.volume12-
dc.citation.number1-
dc.citation.startPage1-
dc.citation.endPage18-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaHealth Care Sciences & Services-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryHealth Care Sciences & Services-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusIDENTIFY ARTHROPLASTY IMPLANTS-
dc.subject.keywordPlusREVISION TOTAL HIP-
dc.subject.keywordPlusRADIOGRAPHS-
dc.subject.keywordPlusHOSPITALS-
dc.subject.keywordPlusCOVID-19-
dc.subject.keywordPlusOUTCOMES-
dc.subject.keywordPlusNETWORK-
dc.subject.keywordAuthorshoulder arthroplasty-
dc.subject.keywordAuthorimplant classification-
dc.subject.keywordAuthorartificial intelligence-
dc.subject.keywordAuthorensemble network-
dc.subject.keywordAuthorshoulder implant system-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Electronics and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Gang Ryung photo

Park, Gang Ryung
College of Engineering (Department of Electronics and Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE