Detailed Information

Cited 18 time in webofscience Cited 20 time in scopus
Metadata Downloads

Diabetic and Hypertensive Retinopathy Screening in Fundus Images Using Artificially Intelligent Shallow Architecturesopen access

Authors
Arsalan, MuhammadHaider, AdnanChoi, JihoPark, Kang Ryoung
Issue Date
Jan-2022
Publisher
MDPI
Keywords
fundus images; diabetic retinopathy; hypertensive retinopathy; retinal disease screening; retinal vasculature; ophthalmic diseases
Citation
Journal of Personalized Medicine, v.12, no.1, pp 1 - 17
Pages
17
Indexed
SCIE
SCOPUS
Journal Title
Journal of Personalized Medicine
Volume
12
Number
1
Start Page
1
End Page
17
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/3787
DOI
10.3390/jpm12010007
ISSN
2075-4426
Abstract
Retinal blood vessels are considered valuable biomarkers for the detection of diabetic retinopathy, hypertensive retinopathy, and other retinal disorders. Ophthalmologists analyze retinal vasculature by manual segmentation, which is a tedious task. Numerous studies have focused on automatic retinal vasculature segmentation using different methods for ophthalmic disease analysis. However, most of these methods are computationally expensive and lack robustness. This paper proposes two new shallow deep learning architectures: dual-stream fusion network (DSF-Net) and dual-stream aggregation network (DSA-Net) to accurately detect retinal vasculature. The proposed method uses semantic segmentation in raw color fundus images for the screening of diabetic and hypertensive retinopathies. The proposed method's performance is assessed using three publicly available fundus image datasets: Digital Retinal Images for Vessel Extraction (DRIVE), Structured Analysis of Retina (STARE), and Children Heart Health Study in England Database (CHASE-DB1). The experimental results revealed that the proposed method provided superior segmentation performance with accuracy (Acc), sensitivity (SE), specificity (SP), and area under the curve (AUC) of 96.93%, 82.68%, 98.30%, and 98.42% for DRIVE, 97.25%, 82.22%, 98.38%, and 98.15% for CHASE-DB1, and 97.00%, 86.07%, 98.00%, and 98.65% for STARE datasets, respectively. The experimental results also show that the proposed DSA-Net provides higher SE compared to the existing approaches. It means that the proposed method detected the minor vessels and provided the least false negatives, which is extremely important for diagnosis. The proposed method provides an automatic and accurate segmentation mask that can be used to highlight the vessel pixels. This detected vasculature can be utilized to compute the ratio between the vessel and the non-vessel pixels and distinguish between diabetic and hypertensive retinopathies, and morphology can be analyzed for related retinal disorders.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Electronics and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Gang Ryung photo

Park, Gang Ryung
College of Engineering (Department of Electronics and Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE