Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Combined feedback-feedforward control of Ćuk CCM converter for achieving fast transient response

Full metadata record
DC Field Value Language
dc.contributor.authorHan, Byeongcheol-
dc.contributor.authorWi, Seok-Min-
dc.contributor.authorKim, Minsung-
dc.date.accessioned2023-04-27T13:40:56Z-
dc.date.available2023-04-27T13:40:56Z-
dc.date.issued2022-01-
dc.identifier.issn1751-858X-
dc.identifier.issn1751-8598-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/3750-
dc.description.abstractThe Cuk converters operating in continuous conduction mode (CCM) can be preferred in applications such as microprocessor power delivery and pulsed load because these circuits have advantages of being able to step up/down, a small number of power components, and low input/output current ripples. However, they show poor transient performance due to right-half-plane-zeros (RHPZs) in the closed-loop transfer function of the Cuk CCM converter. To enhance the transient response, a combined feedback-feedforward control for the Cuk CCM converter is proposed. The proposed control scheme comprises a feedback control signal based on a Lyapunov function and a duty-ratio feedforward control signal. A Lyapunov-function-based controller (LBC) achieves fast dynamic response even under large-signal variations from the operating point. The duty ratio feedforward controller (DFFC) is developed to predict the effect of the disturbances and compensate it, while alleviating the burden of LBC. The proposed control logic makes the closed-loop system of the Cuk CCM converter globally exponentially stable and thus provides a fast transient response even under large-signal variations. To construct the proposed controller, the authors make use of the large-signal averaged model of the Cuk CCM converter, and consider the parasitic elements. To verify the proposed control scheme, numerical simulations and experimental tests are conducted.-
dc.format.extent10-
dc.language영어-
dc.language.isoENG-
dc.publisherJohn Wiley & Sons Ltd.-
dc.titleCombined feedback-feedforward control of Ćuk CCM converter for achieving fast transient response-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1049/cds2.12085-
dc.identifier.scopusid2-s2.0-85106230651-
dc.identifier.wosid000654252100001-
dc.identifier.bibliographicCitationIET Circuits, Devices & Systems, v.16, no.1, pp 71 - 80-
dc.citation.titleIET Circuits, Devices & Systems-
dc.citation.volume16-
dc.citation.number1-
dc.citation.startPage71-
dc.citation.endPage80-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.subject.keywordAuthorClosed Loop Systems-
dc.subject.keywordAuthorControllers-
dc.subject.keywordAuthorElectric Power Transmission-
dc.subject.keywordAuthorFeedforward Control-
dc.subject.keywordAuthorLyapunov Functions-
dc.subject.keywordAuthorTransient Analysis-
dc.subject.keywordAuthorClosed Loop Transfer Function-
dc.subject.keywordAuthorContinuous Conduction Mode-
dc.subject.keywordAuthorFast Transient Response-
dc.subject.keywordAuthorFeed-forward Control Signals-
dc.subject.keywordAuthorFeed-forward Controllers-
dc.subject.keywordAuthorFeedback Control Signals-
dc.subject.keywordAuthorGlobally Exponentially Stable-
dc.subject.keywordAuthorLyapunov Function-based Controllers-
dc.subject.keywordAuthorFeedback-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Electronics and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE