Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Study on sEMG-Based Motor Variability and Functional Connectivity of the Upper Limb Depending on Weight Distributions in a Handle of a Cordless Stick-Type Vacuum Cleaner

Full metadata record
DC Field Value Language
dc.contributor.authorYu, Hayeon-
dc.contributor.authorKang, Eunchae-
dc.contributor.authorChang, Joonho-
dc.date.accessioned2023-04-27T10:40:55Z-
dc.date.available2023-04-27T10:40:55Z-
dc.date.issued2022-07-
dc.identifier.issn1424-8220-
dc.identifier.issn1424-8220-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/2924-
dc.description.abstractThis study investigated the muscle activities, motor variability, and functional connectivity of the upper limb as a function of weight distributions in a handle of a cordless stick-type vacuum cleaner. Eighteen female college students with experience of vacuum cleaner-use participated in testing. Five handles with different centers of mass (CM) were prepared (centroid, top-rear, top-front, bottom-front, and bottom-rear), and electromyography for the muscles of the upper limb were measured during vacuuming. The results showed that the %MVC values of the Extensor Carpi Ulnaris (p = 0.0038) and Deltoid Middle (p = 0.0094) increased but that of the Biceps Brachii (p = 0.0001) decreased, as the CM moved from the top to bottom area of the handle. The motor variability of the Extensor Carpi Ulnaris (p = 0.0335) and Brachioradialis (p = 0.0394) significantly varied depending on the CM locations but failed to show significance in the post-hoc analyses. Lastly, the functional connectivity values of the muscle pairs such as the Extensor Carpi Ulnaris-Deltoid Middle (p = 0.0016), Extensor Carpi Ulnaris-Upper Trapezius (p = 0.0174), Brachioradialis-Biceps Brachii (p = 0.0356), and Biceps Brachii-Upper Trapezius (p = 0.0102) were significantly altered as a function of the CM locations. The lowest functional connectivity was found with the handle of which CM was at centroid.-
dc.format.extent21-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleA Study on sEMG-Based Motor Variability and Functional Connectivity of the Upper Limb Depending on Weight Distributions in a Handle of a Cordless Stick-Type Vacuum Cleaner-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/s22134835-
dc.identifier.scopusid2-s2.0-85132828286-
dc.identifier.wosid000824297900001-
dc.identifier.bibliographicCitationSensors , v.22, no.13, pp 1 - 21-
dc.citation.titleSensors-
dc.citation.volume22-
dc.citation.number13-
dc.citation.startPage1-
dc.citation.endPage21-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusMUTUAL INFORMATION ANALYSIS-
dc.subject.keywordPlusNECK-SHOULDER PAIN-
dc.subject.keywordPlusMUSCLE-ACTIVITY-
dc.subject.keywordPlusBIOMECHANICAL EXPOSURE-
dc.subject.keywordPlusCYCLE VARIABILITY-
dc.subject.keywordPlusTRAPEZIUS MUSCLE-
dc.subject.keywordPlusFORCE-
dc.subject.keywordPlusCOORDINATION-
dc.subject.keywordPlusADAPTATIONS-
dc.subject.keywordPlusDISCOMFORT-
dc.subject.keywordAuthorcordless stick-type vacuum cleaner-
dc.subject.keywordAuthorcenter of mass of a handle-
dc.subject.keywordAuthorEMG analysis-
dc.subject.keywordAuthormotor variability-
dc.subject.keywordAuthorfunctional connectivity-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Industrial and Systems Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chang, Joon Ho photo

Chang, Joon Ho
College of Engineering (Department of Industrial and Systems Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE