Gold nanoclusters supported Molybdenum diselenide-porous carbon composite as an efficient electrocatalyst for selective ultrafast probing of chlorpyrifos-pesticide
- Authors
- Vilian, A. T. Ezhil; Mohammadi, Ali; Han, Soobin; Tiwari, Jitendra N.; Kumar, Krishan; Kumar, Annamalai Senthil; Saravanan, Adhimoorthy; Huh, Yun Suk; Han, Young-Kyu
- Issue Date
- Sep-2023
- Publisher
- Elsevier B.V.
- Keywords
- Porous carbons; Gold nanocluster; Molybdenum diselenide; Amperometry; Chlorpyrifos; Electrochemical sensor
- Citation
- Chemical Engineering Journal, v.472, pp 1 - 11
- Pages
- 11
- Indexed
- SCIE
SCOPUS
- Journal Title
- Chemical Engineering Journal
- Volume
- 472
- Start Page
- 1
- End Page
- 11
- URI
- https://scholarworks.dongguk.edu/handle/sw.dongguk/25867
- DOI
- 10.1016/j.cej.2023.145048
- ISSN
- 1385-8947
1873-3212
- Abstract
- Chlorpyrifos (CPS) is an organophosphorus pesticide widely utilized in agricultural production. Much like other commonly used highly toxic and hazardous substances, is harmful to humans, plants, and animals. Thus, the development of highly efficient electrocatalysts that can monitor and detect levels of CPS in environmental samples is urgently required. This research describes a simple means of synthesizing Au nanoclusters (AuNCs) incorporated into MoSe2-Porous carbons (PCs) via a single-step hydrothermal reaction followed by chemical reduction. AuNC-MoSe2-PC coated Glassy carbon electrodes (GCEs) exhibited excellent electrocatalytic activity, interfacial charge transfer ability (96 Omega), and cathodic peak intensities at a low reduction wave potential (similar to 0.74 V) for sensing CPS. The developed sensor exhibited a wide linear range from 5 to 185 nM, a rapid amperometric response of < 3 s, a low detection limit (0.15 nM), and ultra-sensitivity (27.027 mu A nM(-1) cm(-2)) for CPS at -0.74 V vs. Ag vertical bar AgCl than other reported modified electrodes. Furthermore, the sensor had excellent reproducibility, repeatability, reusability, and long-time stability (88 % activity retention after 1 month) with a relative standard deviation (RSD) of < 5% and exhibited remarkable tolerance for the detection of CPS in the presence of potentially interfering substances. The practical applicability of the sensor was tested for the quantitative analysis of trace CPS levels in paddy water, pond water, and seawater samples, and it demonstrated recoveries of 97.9 to 106.6 % with RSDs below 5% (n = 3), which are comparable to the results of high-performance liquid chromatography.