Cited 1 time in
“Study on Device System to Reduce Tracheal Mucosal Injury in Intubation Patients” [ASME Journal of Medical Devices, 2022, 16(3), p. 031006; DOI: 10.1115/1.4054334]
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Suh, Dai Won | - |
| dc.contributor.author | Lee, Seung Bong | - |
| dc.contributor.author | Kim, Sung Min | - |
| dc.date.accessioned | 2023-04-27T09:40:42Z | - |
| dc.date.available | 2023-04-27T09:40:42Z | - |
| dc.date.issued | 2022-09 | - |
| dc.identifier.issn | 1932-6181 | - |
| dc.identifier.issn | 1932-619X | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/2549 | - |
| dc.description.abstract | The purpose of this study was to develop an automatic bronchial aspiration system to minimize tracheal mucosal damage in ventilator patients. Operation performances of the system's suction pressure, bronchial intubation depth, suction cycle, and tube cuff pressure were tested. To check the clinical results, subjects underwent endoscopy after applying the previous manual method for 24 h. After that, they underwent endoscopy after applying the proposed suction system for 24 h. For quantitative evaluation of test results, the tracheal mucosal injury was divided into the following five grades: grade 0 = normal, grade 1 = erythema or edema, grade 2 = erosion, grade 3 = hemorrhage, and grade 4 = ulcer or necrosis. In the performance test, an error of up to 12 mmHg occurred within the normal operation error range for suction pressure control. The insertion depth control had a maximum error of 7.0 mm within the normal operation error range. On the other hand, there was no error in the time control or the tube cuff pressure control. In the clinical trial, after using the proposed system for five subjects to find changes in tracheal mucosal injury by endoscopy, reduced injury or no change in injury was found. The system proposed in this study is confirmed to be able to remove the sputum while minimizing tracheal mucosal injury that can occur while using the previous manual suction device. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | The American Society of Mechanical Engineers | - |
| dc.title | “Study on Device System to Reduce Tracheal Mucosal Injury in Intubation Patients” [ASME Journal of Medical Devices, 2022, 16(3), p. 031006; DOI: 10.1115/1.4054334] | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1115/1.4054334 | - |
| dc.identifier.scopusid | 2-s2.0-85144601834 | - |
| dc.identifier.wosid | 000835543900011 | - |
| dc.identifier.bibliographicCitation | Journal of Medical Devices, v.16, no.3 | - |
| dc.citation.title | Journal of Medical Devices | - |
| dc.citation.volume | 16 | - |
| dc.citation.number | 3 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
| dc.subject.keywordPlus | NURSES KNOWLEDGE | - |
| dc.subject.keywordPlus | ENDOTRACHEAL | - |
| dc.subject.keywordPlus | PRESSURE | - |
| dc.subject.keywordPlus | TUBE | - |
| dc.subject.keywordAuthor | catheter | - |
| dc.subject.keywordAuthor | intubated patients | - |
| dc.subject.keywordAuthor | suction | - |
| dc.subject.keywordAuthor | tracheal mucosal injury | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.