Cited 12 time in
A Poly(trypan blue)-Modified Anodized Glassy Carbon Electrode for the Sensitive Detection of Dopamine in the Presence of Uric Acid and Ascorbic Acid
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Li, Xiao-Bo | - |
| dc.contributor.author | Rahman, Md. Mahbubur | - |
| dc.contributor.author | Ge, Chuang-Ye | - |
| dc.contributor.author | Xu, Guang-Ri | - |
| dc.contributor.author | Lee, Jae-Joon | - |
| dc.date.accessioned | 2024-09-26T14:31:09Z | - |
| dc.date.available | 2024-09-26T14:31:09Z | - |
| dc.date.issued | 2017 | - |
| dc.identifier.issn | 0013-4651 | - |
| dc.identifier.issn | 1945-7111 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/25495 | - |
| dc.description.abstract | A conducting polymeric film of trypan blue (TB) was deposited onto an anodized glassy carbon electrode (AGCE) surface by electropolymerization. The poly(trypan blue)-modified AGCE was used for the determination of dopamine (DA) in the presence of uric acid (UA) and ascorbic acid (AA). The PTB/AGCE exhibits good electrocatalytic behavior for the oxidation of DA in phosphate buffer solution (PBS, pH 7.0). The electrochemical oxidation signals of DA, UA, and AA are well-resolved into three distinct peaks in cyclic voltammograms (CVs) with the anodic peak potential separations (Delta E-pa) of ca. 186, 145, and 331 mV between AA-DA, DA-UA, and AA-UA, respectively. The Delta E-pa values are large enough to discriminate DA from the interference of AA and UA. A detection limit of ca. 0.36 mu M (S/N = 3) was obtained for the sensing of DA with a linear range of 1-40 mu M in PBS (pH 7.0). The sensor could successfully determine the concentrations of DA in human urine samples with the recoveries of ca. 97.6-102.6%. This approach provides a simple, easy, sensitive, and selective method for the detection of DA in the presence of AA and UA. (C) 2016 The Electrochemical Society. All rights reserved. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | ELECTROCHEMICAL SOC INC | - |
| dc.title | A Poly(trypan blue)-Modified Anodized Glassy Carbon Electrode for the Sensitive Detection of Dopamine in the Presence of Uric Acid and Ascorbic Acid | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1149/2.0371702jes | - |
| dc.identifier.scopusid | 2-s2.0-85037982755 | - |
| dc.identifier.wosid | 000397850800008 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF THE ELECTROCHEMICAL SOCIETY, v.164, no.2, pp B34 - B39 | - |
| dc.citation.title | JOURNAL OF THE ELECTROCHEMICAL SOCIETY | - |
| dc.citation.volume | 164 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | B34 | - |
| dc.citation.endPage | B39 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Electrochemistry | - |
| dc.relation.journalResearchArea | Materials Science | - |
| dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
| dc.relation.journalWebOfScienceCategory | Materials Science, Coatings & Films | - |
| dc.subject.keywordPlus | PROBING BRAIN CHEMISTRY | - |
| dc.subject.keywordPlus | SELECTIVE DETECTION | - |
| dc.subject.keywordPlus | ELECTROCHEMICAL DETERMINATION | - |
| dc.subject.keywordPlus | COATED ELECTRODE | - |
| dc.subject.keywordPlus | PASTE ELECTRODE | - |
| dc.subject.keywordPlus | BIOSENSOR | - |
| dc.subject.keywordPlus | NOREPINEPHRINE | - |
| dc.subject.keywordPlus | CATECHOLAMINE | - |
| dc.subject.keywordPlus | ACTIVATION | - |
| dc.subject.keywordPlus | BEHAVIOR | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
