Cited 76 time in
Highly sensitive and simultaneous detection of dopamine and uric acid at graphene nanoplatelet-modified fluorine-doped tin oxide electrode in the presence of ascorbic acid
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Rahman, Md. Mahbubur | - |
| dc.contributor.author | Lopa, Nasrin Siraj | - |
| dc.contributor.author | Ju, Myung Jong | - |
| dc.contributor.author | Lee, Jae-Joon | - |
| dc.date.accessioned | 2024-09-26T14:31:08Z | - |
| dc.date.available | 2024-09-26T14:31:08Z | - |
| dc.date.issued | 2017-05-01 | - |
| dc.identifier.issn | 1572-6657 | - |
| dc.identifier.issn | 1873-2569 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/25494 | - |
| dc.description.abstract | We developed a graphene nanoplatelet-modified fluorine-doped tin oxide electrode (GNP/FTO) for the simultaneous detection of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA) and investigated the interaction mechanisms of DA, UA, and AA with GNPs considering their charging states at different pH values. Owing to the unique structure and properties originating from the oxygen and nitrogen functional groups at the edges, GNPs showed high electrocatalytic activity for the electrochemical oxidations of AA, DA, and UA with peak-to-peak potential separations (Delta EP) between AA-DA and DA-UA of ca. 0.23 and 0.17 V, respectively. These values are sufficiently high to allow the simultaneous detection of DA and UA without interference from AA. The highly sensitive and stable GNP/FTO sensor showed sensitivities of ca. 0.15 +/- 0.004 and 0.14 +/- 0.007 mu A/mu M, respectively, with detection limits of ca. 0.22 +/- 0.009 and 0.28 +/- 0.009 mu M, respectively, for DA and UA. The sensor could detect DA and UA concentrations in human serum samples with excellent recoveries. (C) 2017 Elsevier B.V. All rights reserved. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | ELSEVIER SCIENCE SA | - |
| dc.title | Highly sensitive and simultaneous detection of dopamine and uric acid at graphene nanoplatelet-modified fluorine-doped tin oxide electrode in the presence of ascorbic acid | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.1016/j.jelechem.2017.03.038 | - |
| dc.identifier.scopusid | 2-s2.0-85015981300 | - |
| dc.identifier.wosid | 000403634500008 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF ELECTROANALYTICAL CHEMISTRY, v.792, pp 54 - 60 | - |
| dc.citation.title | JOURNAL OF ELECTROANALYTICAL CHEMISTRY | - |
| dc.citation.volume | 792 | - |
| dc.citation.startPage | 54 | - |
| dc.citation.endPage | 60 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Electrochemistry | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
| dc.subject.keywordPlus | SELECTIVE DETECTION | - |
| dc.subject.keywordPlus | ELECTROCHEMICAL DETECTION | - |
| dc.subject.keywordPlus | SENSOR | - |
| dc.subject.keywordPlus | NANOCOMPOSITE | - |
| dc.subject.keywordPlus | GOLD | - |
| dc.subject.keywordAuthor | Graphene nanoplatelet | - |
| dc.subject.keywordAuthor | Fluorine-doped tin oxide | - |
| dc.subject.keywordAuthor | Electrospray | - |
| dc.subject.keywordAuthor | Dopamine | - |
| dc.subject.keywordAuthor | Uric acid | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
