Cited 20 time in
Electrochemical Sensitive Determination of Nanomolar Guanine from ZnO Nanorods Coated on Platinum Electrode
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Sharma, Sanjeev K. | - |
| dc.contributor.author | Kaur, Narinder | - |
| dc.contributor.author | Singh, Jasminder | - |
| dc.contributor.author | Sankar, S. | - |
| dc.contributor.author | Gaur, S. S. | - |
| dc.contributor.author | Lee, Sejoon | - |
| dc.contributor.author | Kim, Deuk Young | - |
| dc.contributor.author | Singh, Narinder | - |
| dc.contributor.author | Singh, Harpreet | - |
| dc.date.accessioned | 2024-09-26T14:01:21Z | - |
| dc.date.available | 2024-09-26T14:01:21Z | - |
| dc.date.issued | 2015-11 | - |
| dc.identifier.issn | 1040-0397 | - |
| dc.identifier.issn | 1521-4109 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/25337 | - |
| dc.description.abstract | The crystalline ZnO nanorods, grown on Sisubstrate (100) at a low temperature using a hydrothermal process were used for modification of platinum electrode using PVC and THF for in order to test their chemosensor activity. The modified electrode can be used for selective nanomolar determination of guanine in aqueous media without any interference from other biomolecules. The prepared chemosensor has a lower detection limit of 40 nM for guanine, and a modification of the electrodes with ZnO nanorods increases the reproducibility by reducing the fouling effect caused by the oxidation of biomolecules on the electrode surface as the prepared electrode can be used for more than 30 consecutive scans and can be used for 5 days without any change in current intensity or sensitivity. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | WILEY-V C H VERLAG GMBH | - |
| dc.title | Electrochemical Sensitive Determination of Nanomolar Guanine from ZnO Nanorods Coated on Platinum Electrode | - |
| dc.type | Article | - |
| dc.publisher.location | 독일 | - |
| dc.identifier.doi | 10.1002/elan.201500242 | - |
| dc.identifier.scopusid | 2-s2.0-84954451630 | - |
| dc.identifier.wosid | 000368339700005 | - |
| dc.identifier.bibliographicCitation | ELECTROANALYSIS, v.27, no.11, pp 2537 - 2543 | - |
| dc.citation.title | ELECTROANALYSIS | - |
| dc.citation.volume | 27 | - |
| dc.citation.number | 11 | - |
| dc.citation.startPage | 2537 | - |
| dc.citation.endPage | 2543 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Electrochemistry | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
| dc.subject.keywordPlus | GAS SENSORS | - |
| dc.subject.keywordPlus | ADENINE | - |
| dc.subject.keywordPlus | ARRAYS | - |
| dc.subject.keywordPlus | NANOSTRUCTURES | - |
| dc.subject.keywordPlus | NANOCOMPOSITE | - |
| dc.subject.keywordPlus | CHEMOSENSORS | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordPlus | MODULATION | - |
| dc.subject.keywordPlus | GRAPHENE | - |
| dc.subject.keywordAuthor | ZnO nanorods | - |
| dc.subject.keywordAuthor | Microstructural analysis | - |
| dc.subject.keywordAuthor | Current-voltage (C-V) measurement | - |
| dc.subject.keywordAuthor | Chemosensor activity of Guanine | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.