Electrochemical Sensitive Determination of Nanomolar Guanine from ZnO Nanorods Coated on Platinum Electrode

Full metadata record
DC Field Value Language
dc.contributor.authorSharma, Sanjeev K.-
dc.contributor.authorKaur, Narinder-
dc.contributor.authorSingh, Jasminder-
dc.contributor.authorSankar, S.-
dc.contributor.authorGaur, S. S.-
dc.contributor.authorLee, Sejoon-
dc.contributor.authorKim, Deuk Young-
dc.contributor.authorSingh, Narinder-
dc.contributor.authorSingh, Harpreet-
dc.date.accessioned2024-09-26T14:01:21Z-
dc.date.available2024-09-26T14:01:21Z-
dc.date.issued2015-11-
dc.identifier.issn1040-0397-
dc.identifier.issn1521-4109-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/25337-
dc.description.abstractThe crystalline ZnO nanorods, grown on Sisubstrate (100) at a low temperature using a hydrothermal process were used for modification of platinum electrode using PVC and THF for in order to test their chemosensor activity. The modified electrode can be used for selective nanomolar determination of guanine in aqueous media without any interference from other biomolecules. The prepared chemosensor has a lower detection limit of 40 nM for guanine, and a modification of the electrodes with ZnO nanorods increases the reproducibility by reducing the fouling effect caused by the oxidation of biomolecules on the electrode surface as the prepared electrode can be used for more than 30 consecutive scans and can be used for 5 days without any change in current intensity or sensitivity.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherWILEY-V C H VERLAG GMBH-
dc.titleElectrochemical Sensitive Determination of Nanomolar Guanine from ZnO Nanorods Coated on Platinum Electrode-
dc.typeArticle-
dc.publisher.location독일-
dc.identifier.doi10.1002/elan.201500242-
dc.identifier.scopusid2-s2.0-84954451630-
dc.identifier.wosid000368339700005-
dc.identifier.bibliographicCitationELECTROANALYSIS, v.27, no.11, pp 2537 - 2543-
dc.citation.titleELECTROANALYSIS-
dc.citation.volume27-
dc.citation.number11-
dc.citation.startPage2537-
dc.citation.endPage2543-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.subject.keywordPlusGAS SENSORS-
dc.subject.keywordPlusADENINE-
dc.subject.keywordPlusARRAYS-
dc.subject.keywordPlusNANOSTRUCTURES-
dc.subject.keywordPlusNANOCOMPOSITE-
dc.subject.keywordPlusCHEMOSENSORS-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusMODULATION-
dc.subject.keywordPlusGRAPHENE-
dc.subject.keywordAuthorZnO nanorods-
dc.subject.keywordAuthorMicrostructural analysis-
dc.subject.keywordAuthorCurrent-voltage (C-V) measurement-
dc.subject.keywordAuthorChemosensor activity of Guanine-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Science > Division of Physics & Semiconductor Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE