Microfluidic acoustic trapping force and stiffness measurement using viscous drag effectopen access
- Authors
- Lee, Jungwoo; Jeong, Jong Seob; Shung, K. Kirk
- Issue Date
- Jan-2013
- Publisher
- ELSEVIER SCIENCE BV
- Keywords
- High frequency focused ultrasound; Microfluidic channel; Trap stiffness; Viscous drag force; Chebyshev-windowed chirp coded excitation
- Citation
- ULTRASONICS, v.53, no.1, pp 249 - 254
- Pages
- 6
- Indexed
- SCI
SCIE
SCOPUS
- Journal Title
- ULTRASONICS
- Volume
- 53
- Number
- 1
- Start Page
- 249
- End Page
- 254
- URI
- https://scholarworks.dongguk.edu/handle/sw.dongguk/24894
- DOI
- 10.1016/j.ultras.2012.06.008
- ISSN
- 0041-624X
1874-9968
- Abstract
- It has recently been demonstrated that it was possible to individually trap 70 mu m droplets flowing within a 500 mu m wide microfluidic channel by a 24 MHz single element piezo-composite focused transducer. In order to further develop this non-invasive approach as a microfluidic particle manipulation tool of high precision, the trapping force needs to be calibrated to a known force, i.e., viscous drag force arising from the fluid flow in the channel. However, few calibration studies based on fluid viscosity have been carried out with focused acoustic beams for moving objects in microfluidic environments. In this paper, the acoustic trapping force (F-trapping) and the trap stiffness (or compliance k) are experimentally determined for a streaming droplet in a microfluidic channel. F-trapping is calibrated to viscous drag force produced from syringe pumps. Chebyshev-windowed chirp coded excitation sequences sweeping the frequency range from 18 MHz to 30 MHz is utilized to drive the transducer, enabling the beam transmission through the channel/fluid interface for interrogating the droplets inside the channel. The minimum force (F-min,F-trapping) required for initially immobilizing drifting droplets is determined as a function of pulse repetition frequency (PRF), duty factor (DTF), and input voltage amplitude (V-in) to the transducer. At PRF = 0.1 kHz and DTF = 30%, F-min,F-trapping is increased from 2.2 nN for V-in = 22 V-pp to 3.8 nN for V-in = 54 V-pp. With a fixed V-in = 54 V-pp and DTF = 30%, F-min,F-trapping can be varied from 3.8 nN at PRF = 0.1 kHz to 6.7 nN at PRF = 0.5 kHz. These findings indicate that both higher driving voltage and more frequent beam transmission yield stronger traps for holding droplets in motion. The stiffness k can be estimated through linear regression by measuring the trapping force (F-trapping) corresponding to the displacement (x) of a droplet from the trap center. By plotting F-trapping - x curves for certain values of V-in (22/38/54 V-pp) at DTF = 10% and PRF = 0.1 kHz, k is measured to be 0.09, 0.14, and 0.20 nN/mu m, respectively. With variable PRF from 0.1 to 0.5 kHz at V-in = 54 V-pp, k is increased from 0.20 to 0.42 nN/mu m. It is shown that a higher PRF leads to a more compliant trap formation (or a stronger F-trapping) for a given displacement x. Hence the results suggest that this acoustic trapping method has the potential as a noninvasive manipulation tool for individual moving targets in microfluidics by adjusting the transducer's excitation parameters. (C) 2012 Elsevier B. V. All rights reserved.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Life Science and Biotechnology > Department of Biomedical Engineering > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.