Cited 0 time in
The Design of Multi-Parameter Bio-Signal Sensor for Applying a Smartphone m-Health Service
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Sung Jae | - |
| dc.contributor.author | Lee, Sangjoon | - |
| dc.contributor.author | Jeong, Jea Hoon | - |
| dc.contributor.author | Park, Sung Yun | - |
| dc.contributor.author | Kim, Sung Min | - |
| dc.date.accessioned | 2024-09-26T11:31:59Z | - |
| dc.date.available | 2024-09-26T11:31:59Z | - |
| dc.date.issued | 2014 | - |
| dc.identifier.issn | 1660-9336 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/24826 | - |
| dc.description.abstract | In this study, the multi-parameter bio-signals sensor was proposed to apply smartphones into m-health service application. The proposed sensor for the experiments was consisted of one set of two small devices; the size of each sensor was 25 mm x 20 mm x 4 mm. This sensor was made of either copper or titanium in order to pursue the better body affinity as well as electric conductivity. A manufactured sensor was able to measure for major bio parameters including electrocardiogram (ECG) signal of a channel, temperature,photoplethysmography, and body fat. Further, independent analogue hardware was manufactured to measure the each bio parameter. In results, bio parameters were easily obtained and they will be effectively applied into smartphones. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | TRANS TECH PUBLICATIONS LTD | - |
| dc.title | The Design of Multi-Parameter Bio-Signal Sensor for Applying a Smartphone m-Health Service | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.4028/www.scientific.net/AMM.479-480.713 | - |
| dc.identifier.scopusid | 2-s2.0-84891098286 | - |
| dc.identifier.wosid | 000337850800135 | - |
| dc.identifier.bibliographicCitation | APPLIED SCIENCE AND PRECISION ENGINEERING INNOVATION, PTS 1 AND 2, v.479-480, pp 713 - 718 | - |
| dc.citation.title | APPLIED SCIENCE AND PRECISION ENGINEERING INNOVATION, PTS 1 AND 2 | - |
| dc.citation.volume | 479-480 | - |
| dc.citation.startPage | 713 | - |
| dc.citation.endPage | 718 | - |
| dc.type.docType | Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Materials Science | - |
| dc.relation.journalResearchArea | Mechanics | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
| dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
| dc.relation.journalWebOfScienceCategory | Mechanics | - |
| dc.subject.keywordAuthor | Bio-Signal Sensor | - |
| dc.subject.keywordAuthor | m-Health | - |
| dc.subject.keywordAuthor | e-Health | - |
| dc.subject.keywordAuthor | telehealth | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
