Cited 1 time in
Study on the detection behavior of defect-rich single-walled carbon nanotubes toward perchlorate
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Chen, Yi | - |
| dc.contributor.author | Thuy Hang Nguyen | - |
| dc.contributor.author | Zhang, Shao Lin | - |
| dc.contributor.author | Zhang, Z. | - |
| dc.contributor.author | Yue, Hongyan | - |
| dc.contributor.author | Jian, Jiawen | - |
| dc.contributor.author | Yang, Woo-Chul | - |
| dc.date.accessioned | 2024-09-26T10:02:05Z | - |
| dc.date.available | 2024-09-26T10:02:05Z | - |
| dc.date.issued | 2018-04 | - |
| dc.identifier.issn | 1793-6047 | - |
| dc.identifier.issn | 1793-7213 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/24446 | - |
| dc.description.abstract | Defect-rich single-walled carbon nanotubes (SWCNTs) were prepared by a water vapor flow-assisted chemical vapor deposition process. The correlation between defect density and water flow was quantitively studied using Raman spectrum. The detection capabilities of defective SWCNTs films toward perchlorate anions were investigated. It was found the defect-rich SWCNTs could adsorb more perchlorate anions owing to the strong chemical bonding between anions and defective sites. However, the detective response of defective SWCNTs toward perchlorate was not in compliance with anion adsorption. A tradeoff phenomenon between response and adsorption was found as the defect density of SWCNTs increased. This work is expected to provide a guidance to the future design of SWCNTs based ion detector. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | WORLD SCIENTIFIC PUBL CO PTE LTD | - |
| dc.title | Study on the detection behavior of defect-rich single-walled carbon nanotubes toward perchlorate | - |
| dc.type | Article | - |
| dc.publisher.location | 싱가폴 | - |
| dc.identifier.doi | 10.1142/S1793604718500327 | - |
| dc.identifier.scopusid | 2-s2.0-85044468177 | - |
| dc.identifier.wosid | 000431705500011 | - |
| dc.identifier.bibliographicCitation | FUNCTIONAL MATERIALS LETTERS, v.11, no.2 | - |
| dc.citation.title | FUNCTIONAL MATERIALS LETTERS | - |
| dc.citation.volume | 11 | - |
| dc.citation.number | 2 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Materials Science | - |
| dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
| dc.subject.keywordPlus | ROOM-TEMPERATURE | - |
| dc.subject.keywordPlus | OXIDATION | - |
| dc.subject.keywordPlus | SPECTROSCOPY | - |
| dc.subject.keywordAuthor | Single-walled carbon nanotube | - |
| dc.subject.keywordAuthor | perchlorate | - |
| dc.subject.keywordAuthor | detection | - |
| dc.subject.keywordAuthor | defect density | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
