Cited 36 time in
Hybrid control approach for seismic coupling of two similar adjacent structures
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Kwan-Soon | - |
| dc.contributor.author | Ok, Seung-Yong | - |
| dc.date.accessioned | 2024-09-25T03:01:08Z | - |
| dc.date.available | 2024-09-25T03:01:08Z | - |
| dc.date.issued | 2015-08-04 | - |
| dc.identifier.issn | 0022-460X | - |
| dc.identifier.issn | 1095-8568 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/23488 | - |
| dc.description.abstract | This study describes an optimal hybrid control approach of two similar adjacent buildings for seismic performance improvement, for which the passive dampers are used as link members between the two parallel buildings and the active control devices are installed as tendon-type devices between two successive floors in the buildings. Throughout this configuration, the passive coupling dampers modulate the relative responses between the two buildings and the active control devices modulate the inter-story responses of each building. In order to achieve global optimal control performance, genetic algorithm is employed to perform an integrated design approach for the system of buildings and hybrid control devices. Through the optimization process, the passive and active devices are optimally distributed along the floors and, simultaneously, their clamping capacities and active controllers are configured in accordance with the distribution. The proposed approach is demonstrated in comparison with typical active control system which consists of two independent active systems without any connections between two buildings, each being optimal for one particular building. The numerical simulation results for a system of 20-story and 16-story buildings reveal that the proposed system can guarantee the competent control performance over the typical independent active system with less control forces and powers. As a result, it is proved that the proposed approach enables the simultaneous optimization of the control performance and the control cost. (C) 2015 Elsevier Ltd. All rights reserved. | - |
| dc.format.extent | 17 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD | - |
| dc.title | Hybrid control approach for seismic coupling of two similar adjacent structures | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.jsv.2015.03.028 | - |
| dc.identifier.scopusid | 2-s2.0-84929507082 | - |
| dc.identifier.wosid | 000354181500001 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF SOUND AND VIBRATION, v.349, pp 1 - 17 | - |
| dc.citation.title | JOURNAL OF SOUND AND VIBRATION | - |
| dc.citation.volume | 349 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 17 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Acoustics | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Mechanics | - |
| dc.relation.journalWebOfScienceCategory | Acoustics | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
| dc.relation.journalWebOfScienceCategory | Mechanics | - |
| dc.subject.keywordPlus | OPTIMAL-DESIGN | - |
| dc.subject.keywordPlus | BUILDINGS | - |
| dc.subject.keywordPlus | ALGORITHM | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
