Cited 8 time in
Successful removal of phenol from industrial wastewater using novel hydrophobic modified ceramic hollow fiber membrane contactors with remarkably high stability
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Hong Joo | - |
| dc.contributor.author | Park, Chan-gyu | - |
| dc.contributor.author | Yeo, In-seol | - |
| dc.contributor.author | Park, Jung Hoon | - |
| dc.contributor.author | Magnone, Edoardo | - |
| dc.date.accessioned | 2023-04-27T08:41:01Z | - |
| dc.date.available | 2023-04-27T08:41:01Z | - |
| dc.date.issued | 2022-10 | - |
| dc.identifier.issn | 1226-086X | - |
| dc.identifier.issn | 1876-794X | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/2322 | - |
| dc.description.abstract | Wastewater pollution has become a serious global issue in recent years. One of the most prevalent indus-trial wastewater contaminants is phenol, a hazardous aromatic organic molecule. Part of the answer is to promote novel technologies for reducing the quantity of phenol (PH) in industrial wastewater. The liq-uid-liquid (LL) PH extraction process through a hydrophobically modified ceramic (Al2O3) hollow fiber (Al2O3HF) membrane contactor from an aqueous solution with a high initial concentration of PH (3500 ppm) was studied for the first time. Al2O3HF membranes were prepared by a combined phase -inversion and sintering process. All membranes were fully characterized. PH extraction process tests were performed at a temperature range from room temperature to 50 & DEG;C. Under room temperature con-ditions, the total PH extraction (%) was 80 % with respect to the initial PH concentration. The total PH extraction (%) increases as the temperature increases, reaching a value of about 91 % at 50 & DEG;C. The dura-bility of the Al2O3HF membrane contactor during a long-term LL PH extraction was investigated at 40 & DEG;C. The Al2O3HF membrane contactor exhibited no degradation in LL PH removal ability after a 100-hour LL PH extraction operation.(c) 2022 The Korean Society of Industrial and Engineering Chemistry. Published by Elsevier B.V. All rights reserved. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국공업화학회 | - |
| dc.title | Successful removal of phenol from industrial wastewater using novel hydrophobic modified ceramic hollow fiber membrane contactors with remarkably high stability | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1016/j.jiec.2022.07.029 | - |
| dc.identifier.scopusid | 2-s2.0-85135012395 | - |
| dc.identifier.wosid | 000862895800011 | - |
| dc.identifier.bibliographicCitation | Journal of Industrial and Engineering Chemistry, v.114, pp 402 - 408 | - |
| dc.citation.title | Journal of Industrial and Engineering Chemistry | - |
| dc.citation.volume | 114 | - |
| dc.citation.startPage | 402 | - |
| dc.citation.endPage | 408 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002902736 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Chemical | - |
| dc.subject.keywordPlus | AQUEOUS-SOLUTIONS | - |
| dc.subject.keywordPlus | SOLVENT-EXTRACTION | - |
| dc.subject.keywordPlus | PERTRACTION | - |
| dc.subject.keywordPlus | RECOVERY | - |
| dc.subject.keywordPlus | SEPARATION | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordAuthor | Industrial wastewater treatment | - |
| dc.subject.keywordAuthor | Membrane process | - |
| dc.subject.keywordAuthor | Phenol | - |
| dc.subject.keywordAuthor | High phenol removal | - |
| dc.subject.keywordAuthor | High process stability | - |
| dc.subject.keywordAuthor | Liquid-liquid ceramic hollow fiber membrane contactor | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
