Cited 3 time in
Small bowel cleanliness in capsule endoscopy: a case-control study using validated artificial intelligence algorithm
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Oh, Dong Jun | - |
| dc.contributor.author | Hwang, Youngbae | - |
| dc.contributor.author | Nam, Ji Hyung | - |
| dc.contributor.author | Lim, Yun Jeong | - |
| dc.date.accessioned | 2023-04-27T08:41:00Z | - |
| dc.date.available | 2023-04-27T08:41:00Z | - |
| dc.date.issued | 2022-10 | - |
| dc.identifier.issn | 2045-2322 | - |
| dc.identifier.issn | 2045-2322 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/2317 | - |
| dc.description.abstract | Small bowel capsule endoscopy (SBCE) may need to be performed immediately after colonoscopy without additional bowel preparation if active small bowel diseases are suspected. However, it is unclear whether the small bowel cleanliness is adequately maintained even after SBCE is performed immediately after colonoscopy. We compared the small bowel cleanliness scores of the study group (SBCE immediately after colonoscopy) and control group (SBCE alone) using a validated artificial intelligence (AI) algorithm (cut-off score > 3.25 for adequate). Cases of SBCE in which polyethylene glycol was used were included retrospectively. Among 85 enrolled cases, 50 cases (58.8%) were the study group. The mean time from the last dose of purgative administration to SBCE was 6.86 +/- 0.94 h in the study group and 3.00 +/- 0.18 h in the control group. Seventy-five cases (88.2%) were adequate small bowel cleanliness, which was not different between the two groups. The mean small bowel cleanliness score for the study group was 3.970 +/- 0.603, and for the control group was 3.937 +/- 0.428. In the study group, better colon preparation resulted in a higher small bowel cleanliness score (p = 0.015). Small bowel cleanliness was also adequately maintained in SBCE immediately after colonoscopy. There was no difference between the time and volume of purgative administration and small bowel cleanliness. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Nature Portfolio | - |
| dc.title | Small bowel cleanliness in capsule endoscopy: a case-control study using validated artificial intelligence algorithm | - |
| dc.type | Article | - |
| dc.publisher.location | 독일 | - |
| dc.identifier.doi | 10.1038/s41598-022-23181-1 | - |
| dc.identifier.scopusid | 2-s2.0-85140923150 | - |
| dc.identifier.wosid | 000876608900035 | - |
| dc.identifier.bibliographicCitation | Scientific Reports, v.12, no.1 | - |
| dc.citation.title | Scientific Reports | - |
| dc.citation.volume | 12 | - |
| dc.citation.number | 1 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
| dc.relation.journalWebOfScienceCategory | Multidisciplinary Sciences | - |
| dc.subject.keywordPlus | DEVICE-ASSISTED ENTEROSCOPY | - |
| dc.subject.keywordPlus | DISORDERS EUROPEAN-SOCIETY | - |
| dc.subject.keywordPlus | DIAGNOSIS | - |
| dc.subject.keywordPlus | QUALITY | - |
| dc.subject.keywordAuthor | Cathartics | - |
| dc.subject.keywordAuthor | Laxative | - |
| dc.subject.keywordAuthor | Algorithm | - |
| dc.subject.keywordAuthor | Artificial Intelligence | - |
| dc.subject.keywordAuthor | Capsule Endoscopy | - |
| dc.subject.keywordAuthor | Case Control Study | - |
| dc.subject.keywordAuthor | Retrospective Study | - |
| dc.subject.keywordAuthor | Algorithms | - |
| dc.subject.keywordAuthor | Artificial Intelligence | - |
| dc.subject.keywordAuthor | Capsule Endoscopy | - |
| dc.subject.keywordAuthor | Case-control Studies | - |
| dc.subject.keywordAuthor | Cathartics | - |
| dc.subject.keywordAuthor | Retrospective Studies | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
