Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

혈관치료용 카테터 회전 및 풀백 구동 시스템 개발Development of Rotation and Pull-back Drive System of Catheter for Vascular Treatment

Other Titles
Development of Rotation and Pull-back Drive System of Catheter for Vascular Treatment
Authors
설재호서명재전종혁김성민임홍석
Issue Date
Jul-2024
Publisher
한국정밀공학회
Keywords
Pull-back; Catheter; Varicose vein; Minimal invasive surgery; Hand piece; 풀백; 카테터; 하지정맥류; 최소침습술; 핸드피스
Citation
한국정밀공학회지, v.41, no.7, pp 561 - 567
Pages
7
Indexed
SCOPUS
KCI
Journal Title
한국정밀공학회지
Volume
41
Number
7
Start Page
561
End Page
567
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/22663
DOI
10.7736/JKSPE.024.036
ISSN
1225-9071
2287-8769
Abstract
Varicose vein treatments range from conventional surgical ligation and sclerotherapy to venous closure using biologicaladhesives. However, considering ease of procedure, recovery time, and cosmetic outcomes like minimal scarring, minimallyinvasive techniques employing lasers or radiofrequency are preferred. The efficacy of these methods heavily relies on clinicianexpertise and ultrasound imaging, with manual catheter retraction during cauterization presenting challenges, such asoverlapping or untreated areas, especially in long vessels exceeding 1 meter, leading to increased procedure time andoperator fatigue. To address these issues, we propose an automated catheter procedure for varicose veins. This systemfeatures a handpiece for energy generation control (laser, radiofrequency) operated near the clinician for convenience. Wedesigned a pullback system that enables constant speed rotation and forward/backward movements of the catheter withoutmoving the handpiece. Through handpiece operation, the catheter rotates at a set speed, and a roller-driven pullback actionoccurs as it winds on a reel, expanding the diameter of the reel for retraction while remaining stationary. Conversely, reducingthe diameter of the reel facilitates forward movement. The length adjustment of the catheter based on winding turns on thereel makes it adaptable for various vascular procedures, enhancing the procedural accuracy and operator convenience.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Science and Biotechnology > Department of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sung Min photo

Kim, Sung Min
College of Life Science and Biotechnology (Department of Biomedical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE