Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Synthesis and characterization of nitrogen-doped-MWCNT@cobalt oxide for nerve agent simulant detection

Full metadata record
DC Field Value Language
dc.contributor.authorLama, Sanjeeb-
dc.contributor.authorChoi, Hyeong-Seon-
dc.contributor.authorRamesh, Sivalingam-
dc.contributor.authorLee, Young Jun-
dc.contributor.authorKim, Joo Hyung-
dc.date.accessioned2024-08-08T12:31:25Z-
dc.date.available2024-08-08T12:31:25Z-
dc.date.issued2024-05-
dc.identifier.issn2045-2322-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/22135-
dc.description.abstractOrganophosphorus nerve agents are toxic compounds that disrupt neuromuscular transmission by inhibiting the neurotransmitter enzyme, acetylcholinesterase, leading to rapid death. A hybrid composite was synthesized using a hydrothermal process for the early detection of dimethyl methyl phosphonate (DMMP), a simulant of the G-series nerve agent, sarin. Quartz crystal microbalance (QCM) and surface acoustic wave (SAW) sensors were used as detectors. Nitrogen-doped multiwalled carbon nanotubes (N-MWCNTs), cobalt oxide (Co3O4), and N-MWCNT@Co3O4 were compared to detect DMMP concentrations of 25–150 ppm. At 25 ppm, the differential frequencies (Δf) of the N-MWCNT, Co3O4, and N-MWCNT@Co3O4 sensors were 5.8, 2.3, and 99.5 Hz, respectively. The selectivity results revealed a preference for the DMMP rather than potential interference. The coefficients of determination (R2) of the N-MWCNT, Co3O4, and N-MWCNT@Co3O4 sensors for detecting 25–150 ppm DMMP were 0.983, 0.986, and 0.999, respectively. The response times of the N-MWCNT, Co3O4, and N-MWCNT@Co3O4 sensors for detecting 100 ppm DMMP were 25, 27, and 34 s, respectively, while the corresponding recovery times were 85, 105, and 181 s. The repeatability results revealed the reversible adsorption and desorption phenomena for the fixed DMMP concentration of 100 ppm. These unique findings show that synthesized materials can be used to detect organophosphorus nerve agents. © The Author(s) 2024.-
dc.language영어-
dc.language.isoENG-
dc.publisherNature Portfolio-
dc.titleSynthesis and characterization of nitrogen-doped-MWCNT@cobalt oxide for nerve agent simulant detection-
dc.typeArticle-
dc.publisher.location독일-
dc.identifier.doi10.1038/s41598-024-56354-1-
dc.identifier.scopusid2-s2.0-85193996789-
dc.identifier.wosid001229023500121-
dc.identifier.bibliographicCitationScientific Reports, v.14, no.1-
dc.citation.titleScientific Reports-
dc.citation.volume14-
dc.citation.number1-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusQUARTZ-CRYSTAL MICROBALANCE-
dc.subject.keywordPlusCARBON NANOTUBE COMPOSITES-
dc.subject.keywordPlusDIMETHYL METHYLPHOSPHONATE-
dc.subject.keywordPlusDMMP-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordPlusCO3O4-
dc.subject.keywordPlusADSORPTION-
dc.subject.keywordPlusPATTERN-
dc.subject.keywordPlusARRAY-
dc.subject.keywordAuthorCarbon nanotube-
dc.subject.keywordAuthorCobalt oxide-
dc.subject.keywordAuthorDimethyl methyl phosphonate-
dc.subject.keywordAuthorHydrothermal process-
dc.subject.keywordAuthorNerve agents-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Energy and Materials Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE