Detailed Information

Cited 6 time in webofscience Cited 6 time in scopus
Metadata Downloads

Chemical vapor deposition-grown single-layer graphene-supported nanostructured Co3O4 composite as binder-free electrode for asymmetric supercapacitor and electrochemical detection of caffeic acid

Authors
Haldorai, YuvarajKumar, Raju SureshRamesh, SivalingamKumar, R.T. RajendraYang, Woochul
Issue Date
Aug-2024
Publisher
Elsevier BV
Keywords
Asymmetric supercapacitor; Cobalt oxide; Electrochemical sensor; Monolayer graphene
Citation
Journal of Alloys and Compounds, v.995, pp 1 - 12
Pages
12
Indexed
SCIE
SCOPUS
Journal Title
Journal of Alloys and Compounds
Volume
995
Start Page
1
End Page
12
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/22072
DOI
10.1016/j.jallcom.2024.174738
ISSN
0925-8388
1873-4669
Abstract
In this study, we developed a monolayer graphene/nanostructured cobalt oxide (MLG/Co3O4) composite for asymmetric supercapacitor and electrochemical sensor applications. The MLG was grown by chemical vapor deposition process and the Co3O4 nanostructures were electrodeposited on the MLG surface. Scanning electron microscopy proved that there were flower-like nanostructured Co3O4 densely electrodeposited on the MLG surface. At a current density of 3 mA cm−2, the MLG/Co3O4 composite produced an areal capacitance of 3.73 F cm−2. After 10,000 cycles, the composite electrode still had 93.6 % of its initial capacitance at 5 mA cm−2. The asymmetric system displayed an areal capacitance of 929 mF cm−2 at 4 mA cm−2 with good cycle stability. The asymmetric electrode produced a specific energy of 51 μWh cm−2 and a specific power of 11.1 mW cm−2. Cyclic voltammetric measurements demonstrated that the composite showed redox peaks at 0.48 eV and 0.09 eV toward the determination of CA. With a sensitivity of 0.13 µA/µM/cm2 and a limit of detection of 0.009 µM, the composite showed CA concentrations, ranging from 0.5 to 480 M. The composite displayed excellent selectivity and the current produced for the interfering compounds was exceedingly low. Using the composite electrode, the spiked CA in red wine and green tea samples recovered remarkably effectively. © 2024 Elsevier B.V.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical, Robotics and Energy Engineering > 1. Journal Articles
College of Natural Science > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yang, Woo Chul photo

Yang, Woo Chul
College of Natural Science (Department of Physics)
Read more

Altmetrics

Total Views & Downloads

BROWSE