Cited 1 time in
Optimal Nozzle Position and Patient's Posture to Enhance Drug Delivery into the Peritoneum during Rotational Intraperitoneal Pressurized Aerosol Chemotherapy in a Swine Model
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Hwang, Dong Won | - |
| dc.contributor.author | Lee, Eun Ji | - |
| dc.contributor.author | Chung, Joo Yeon | - |
| dc.contributor.author | Lee, Eun Joo | - |
| dc.contributor.author | Kim, Dayoung | - |
| dc.contributor.author | Oh, Soo Hyun | - |
| dc.contributor.author | Lee, Seungmee | - |
| dc.contributor.author | Yim, Ga Won | - |
| dc.contributor.author | Shim, Seung-Hyuk | - |
| dc.contributor.author | Lee, Sung Jong | - |
| dc.contributor.author | Lee, San-Hui | - |
| dc.contributor.author | Park, Ji Won | - |
| dc.contributor.author | Chang, Suk-Joon | - |
| dc.contributor.author | Pak, Kyung Ah | - |
| dc.contributor.author | Park, Soo Jin | - |
| dc.contributor.author | Kim, Hee Seung | - |
| dc.date.accessioned | 2024-08-08T11:31:49Z | - |
| dc.date.available | 2024-08-08T11:31:49Z | - |
| dc.date.issued | 2022-11 | - |
| dc.identifier.issn | 2075-4426 | - |
| dc.identifier.issn | 2075-4426 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/21805 | - |
| dc.description.abstract | Even though rotational intraperitoneal pressurized aerosol chemotherapy (RIPAC) has been developed to improve the distribution and penetration depth of anti-cancer agents by pressurized intraperitoneal aerosol chemotherapy (PIPAC), the optimal nozzle position and patient's posture have not been investigated. Thus, we used nine pigs weighing 50-60 kg, and sprayed 150 mL of 1% methylene blue as an aerosol through the nozzle, DreamPen (R) (Dreampac Corp., Wonju, Republic of Korea), with a flow rate of 0.6 ml/min under a pressure of 140 to 150 psi for RIPAC in six and three pigs with supine and Trendelenburg positions, respectively. When we evaluated its distribution and penetration depth, even distribution among 13 regions of the abdomen was observed in three pigs with Trendelenburg position regardless of the depth of the nozzle. Regarding penetration depth, the numbers of regions with maximal penetration depth were high in the 2 cm depth of the nozzle with supine position (n = 5) and the 4 cm depth with Trendelenburg position (n = 3). Conclusively, even distribution and maximal penetration of anti-cancer agents can be expected during RIPAC in the medium depth (4 cm) between the nozzle inlet and the visceral peritoneum located on the opposite side of it and the Trendelenburg position. | - |
| dc.format.extent | 9 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | MDPI | - |
| dc.title | Optimal Nozzle Position and Patient's Posture to Enhance Drug Delivery into the Peritoneum during Rotational Intraperitoneal Pressurized Aerosol Chemotherapy in a Swine Model | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.3390/jpm12111799 | - |
| dc.identifier.scopusid | 2-s2.0-85149683114 | - |
| dc.identifier.wosid | 000895538600001 | - |
| dc.identifier.bibliographicCitation | Journal of Personalized Medicine, v.12, no.11, pp 1 - 9 | - |
| dc.citation.title | Journal of Personalized Medicine | - |
| dc.citation.volume | 12 | - |
| dc.citation.number | 11 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 9 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Health Care Sciences & Services | - |
| dc.relation.journalResearchArea | General & Internal Medicine | - |
| dc.relation.journalWebOfScienceCategory | Health Care Sciences & Services | - |
| dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
| dc.subject.keywordPlus | DISTRIBUTION PATTERN | - |
| dc.subject.keywordPlus | OVARIAN | - |
| dc.subject.keywordPlus | CARCINOMATOSIS | - |
| dc.subject.keywordPlus | DOXORUBICIN | - |
| dc.subject.keywordPlus | CANCER | - |
| dc.subject.keywordPlus | PIPAC | - |
| dc.subject.keywordAuthor | peritoneal metastasis | - |
| dc.subject.keywordAuthor | rotational intraperitoneal pressurized aerosol chemotherapy | - |
| dc.subject.keywordAuthor | nozzle position | - |
| dc.subject.keywordAuthor | posture | - |
| dc.subject.keywordAuthor | distribution | - |
| dc.subject.keywordAuthor | penetration | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
