Knee Measurement System with Osteoarthritis Levels Using Artificial Cartilage and Skeletons
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kang, Minchae | - |
| dc.contributor.author | Seo, Suyeon | - |
| dc.contributor.author | Lee, Hyewon | - |
| dc.contributor.author | Han, Min-Woo | - |
| dc.date.accessioned | 2024-08-08T11:01:13Z | - |
| dc.date.available | 2024-08-08T11:01:13Z | - |
| dc.date.issued | 2024-03 | - |
| dc.identifier.issn | 2313-7673 | - |
| dc.identifier.issn | 2313-7673 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/21583 | - |
| dc.description.abstract | Knee osteoarthritis (OA), also known as degenerative arthritis, is a disease characterized by irreversible changes in the cartilage and bones comprising the joints, resulting in pain, impaired function, and deformity. Furthermore, independent of natural aging, the rate of change in joint cartilage has increased in recent years, which is mainly attributed to environmental factors. The rising incidence of knee-related disorders emphasizes the importance of analyzing the morphology and kinematics of knee structure. This study introduces a knee measurement system designed to replicate the motions of knee using 3D-printing technology, providing insights into knee mechanics with OA level. The research explores the stages of OA using the Kellgren-Lawrence (KL) grade scale, highlighting the variations in the force applied to the knee bone according to movement. The developed knee-simulation system, utilizing the four-bar-link theory, presents a novel approach to studying OA levels 0 to 4. As OA progresses, the cartilage deteriorates, affecting the movement of OA. The OA-based knee measurement system that incorporates soft tissues and skeletons can assist in developing a personalized diagnostic approach for knee disease. This will also help to enhance surgical effectiveness by facilitating the creation of personalized prosthetic joints for individual patients and offering a customized surgical simulation. | - |
| dc.format.extent | 16 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | MDPI AG | - |
| dc.title | Knee Measurement System with Osteoarthritis Levels Using Artificial Cartilage and Skeletons | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.3390/biomimetics9030166 | - |
| dc.identifier.scopusid | 2-s2.0-85188677351 | - |
| dc.identifier.wosid | 001191380300001 | - |
| dc.identifier.bibliographicCitation | Biomimetics, v.9, no.3, pp 1 - 16 | - |
| dc.citation.title | Biomimetics | - |
| dc.citation.volume | 9 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 16 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Materials Science | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
| dc.relation.journalWebOfScienceCategory | Materials Science, Biomaterials | - |
| dc.subject.keywordPlus | MEASURED IN-VIVO | - |
| dc.subject.keywordPlus | JOINT FORCES | - |
| dc.subject.keywordPlus | RISK-FACTORS | - |
| dc.subject.keywordPlus | PATHOGENESIS | - |
| dc.subject.keywordPlus | MECHANISM | - |
| dc.subject.keywordPlus | STRESSES | - |
| dc.subject.keywordPlus | DISEASE | - |
| dc.subject.keywordPlus | ADULTS | - |
| dc.subject.keywordPlus | PAIN | - |
| dc.subject.keywordAuthor | 3D printing | - |
| dc.subject.keywordAuthor | soft polymer | - |
| dc.subject.keywordAuthor | artificial joint | - |
| dc.subject.keywordAuthor | mimicking knee movement | - |
| dc.subject.keywordAuthor | four-bar-link theory | - |
| dc.subject.keywordAuthor | surgical simulator | - |
| dc.subject.keywordAuthor | Kellgren-Lawrence grade | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.