Cited 13 time in
Optimization of HPLC–CAD method for simultaneous analysis of different lipids in lipid nanoparticles with analytical QbD
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Ki Hyun | - |
| dc.contributor.author | Lee, Ji Eun | - |
| dc.contributor.author | Lee, Jae Chul | - |
| dc.contributor.author | Maharjan, Ravi | - |
| dc.contributor.author | Oh, Hyunsuk | - |
| dc.contributor.author | Lee, Kyeong | - |
| dc.contributor.author | Kim, Nam Ah | - |
| dc.contributor.author | Jeong, Seong Hoon | - |
| dc.date.accessioned | 2024-08-08T09:32:14Z | - |
| dc.date.available | 2024-08-08T09:32:14Z | - |
| dc.date.issued | 2023-10 | - |
| dc.identifier.issn | 0021-9673 | - |
| dc.identifier.issn | 1873-3778 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/21034 | - |
| dc.description.abstract | Since lipid nanoparticles (LNP) have emerged as a potent drug delivery system, the objective of this study was to develop and optimize a robust high-performance liquid chromatography with charged aerosol detectors (HPLC–CAD) method to simultaneously quantify different lipids in LNPs using the analytical quality by design (AQbD) approach. After defining analytical target profile (ATP), critical method attributes (CMAs) were established as a resolution between the closely eluting lipid peaks and the total analysis time. Thus, potential high-risk method parameters were identified through the initial risk assessment. These parameters were screened using Plackett–Burman design, and three critical method parameters (CMPs)—MeOH ratio, flow rate, and column temperature—were selected for further optimization. Box–Behnken design was employed to develop the quadratic models that explain the relationship between the CMPs and CMAs and to determine the optimal operating conditions. Moreover, to ensure the robustness of the developed method, a method operable design region (MODR) was established using the Monte Carlo simulation. The MODR was identified within the probability map, where the risk of failure to achieve the desired CMAs was less than 1%. The optimized method was validated according to the ICH guidelines (linearity: R2 > 0.995, accuracy: 97.15–100.48% recovery, precision: RSD < 5%) and successfully applied for the analysis of the lipid in the LNP samples. The development of the analytical method to quantify the lipids is essential for the formulation development and quality control of LNP-based drugs since the potency of LNPs is significantly dependent on the compositions and contents of the lipids in the formation. © 2023 Elsevier B.V. | - |
| dc.format.extent | 9 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier B.V. | - |
| dc.title | Optimization of HPLC–CAD method for simultaneous analysis of different lipids in lipid nanoparticles with analytical QbD | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.chroma.2023.464375 | - |
| dc.identifier.scopusid | 2-s2.0-85171453044 | - |
| dc.identifier.wosid | 001084270500001 | - |
| dc.identifier.bibliographicCitation | Journal of Chromatography A, v.1709, pp 1 - 9 | - |
| dc.citation.title | Journal of Chromatography A | - |
| dc.citation.volume | 1709 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 9 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalWebOfScienceCategory | Biochemical Research Methods | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.subject.keywordPlus | COLUMN EFFICIENCY | - |
| dc.subject.keywordPlus | SIRNA | - |
| dc.subject.keywordPlus | PARTICLES | - |
| dc.subject.keywordPlus | DESIGN | - |
| dc.subject.keywordAuthor | Analytical quality by design | - |
| dc.subject.keywordAuthor | Charged aerosol detector | - |
| dc.subject.keywordAuthor | Design of experiment | - |
| dc.subject.keywordAuthor | Lipid nanoparticles | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
