Detailed Information

Cited 4 time in webofscience Cited 5 time in scopus
Metadata Downloads

Evaluation of bond strength of porous cobalt-chromium metal and pressed ceramic fabricated by additive manufacturing

Full metadata record
DC Field Value Language
dc.contributor.authorBae, Eun-Jeong-
dc.contributor.authorKim, Hyun-Soo-
dc.contributor.authorLim, Joong Yeon-
dc.date.accessioned2024-08-08T07:30:32Z-
dc.date.available2024-08-08T07:30:32Z-
dc.date.issued2020-12-
dc.identifier.issn0022-3913-
dc.identifier.issn1097-6841-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/19497-
dc.description.abstractStatement of problem. A high metal-ceramic bond strength is important for successful dental restorations. However, studies on the evaluation of the bond strength of porous metal-ceramic restorations compared with conventional ones are scarce. Purpose. The purpose of this in vitro study was to compare the bond strength of a porous metaleceramic structure with conventional metal-ceramic restorations. Material and methods. Ten porous specimens were fabricated by selective laser sintering (SLS) according to the International Organization for Standardization 9693-1:2012, 10 specimens without porosity by SLS, and 10 cobalt-chromium (Co-Cr) cast specimens without porosity. The ceramic was applied with the pressing method. A 3-point bend test was performed with a universal testing machine, and the data were statistically analyzed by using 1-way analysis of variance (alpha=.05). Results. The mean +/- standard deviation bond strength of the porous group fabricated by SLS was the lowest (35.6 +/- 9.1 MPa), that of the group without porosity in the casting method was 43.5 +/- 7.8 MPa, and that of the group without porosity fabricated by SLS was the highest (47.7 +/- 4.5 MPa); these were statistically similar (P=.058). Conclusions. Although the porous structure reported the lowest bond strength among the 3 sets of test specimens, its bond strength was higher than the International Standards Organization standard of 25 MPa.-
dc.language영어-
dc.language.isoENG-
dc.publisherMOSBY-ELSEVIER-
dc.titleEvaluation of bond strength of porous cobalt-chromium metal and pressed ceramic fabricated by additive manufacturing-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1016/j.prosdent.2020.05.025-
dc.identifier.scopusid2-s2.0-85090486596-
dc.identifier.wosid000597140200015-
dc.identifier.bibliographicCitationJOURNAL OF PROSTHETIC DENTISTRY, v.124, no.6, pp 808.e1 - 808.e5-
dc.citation.titleJOURNAL OF PROSTHETIC DENTISTRY-
dc.citation.volume124-
dc.citation.number6-
dc.citation.startPage808.e1-
dc.citation.endPage808.e5-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaDentistry, Oral Surgery & Medicine-
dc.relation.journalWebOfScienceCategoryDentistry, Oral Surgery & Medicine-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical, Robotics and Energy Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Joong Yeon photo

Lim, Joong Yeon
College of Engineering (Department of Mechanical, Robotics and Energy Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE