Cited 39 time in
Experimental Validation of a Fuzzy Adaptive Voltage Controller for Three-Phase PWM Inverter of a Standalone DG Unit
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Dang, Dong Quang | - |
| dc.contributor.author | Choi, Young-Sik | - |
| dc.contributor.author | Choi, Han Ho | - |
| dc.contributor.author | Jung, Jin-Woo | - |
| dc.date.accessioned | 2024-08-08T07:01:01Z | - |
| dc.date.available | 2024-08-08T07:01:01Z | - |
| dc.date.issued | 2015-06 | - |
| dc.identifier.issn | 1551-3203 | - |
| dc.identifier.issn | 1941-0050 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/19255 | - |
| dc.description.abstract | This paper investigates a disturbance observer-based fuzzy adaptive voltage controller for three-phase pulse width modulation (PWM) inverter of a standalone distributed generation (DG) unit in the existence of system uncertainties. The proposed control law includes only a voltage control loop, which has advantages such as a simple control structure and a fast transient response due to the direct control of the output voltage. Next, a disturbance observer is presented to reduce the number of the sensors and improve the control performance. Besides, the proposed strategy is insensitive to any system uncertainties, because it does not require any accurate knowledge about system parameter and load current information. Experimental results on a prototype DG unit with a TMS320F28335 DSP are demonstrated to validate the superior performance of the proposed control scheme over the conventional proportional-derivative (PD) control method and feedback linearization control (FLC) method under sudden load disturbances, system uncertainties, and nonlinear load. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
| dc.title | Experimental Validation of a Fuzzy Adaptive Voltage Controller for Three-Phase PWM Inverter of a Standalone DG Unit | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/TII.2015.2416981 | - |
| dc.identifier.scopusid | 2-s2.0-84937429292 | - |
| dc.identifier.wosid | 000356180000007 | - |
| dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, v.11, no.3, pp 632 - 641 | - |
| dc.citation.title | IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS | - |
| dc.citation.volume | 11 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 632 | - |
| dc.citation.endPage | 641 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Automation & Control Systems | - |
| dc.relation.journalResearchArea | Computer Science | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Automation & Control Systems | - |
| dc.relation.journalWebOfScienceCategory | Computer Science, Interdisciplinary Applications | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Industrial | - |
| dc.subject.keywordPlus | MODEL-PREDICTIVE CONTROL | - |
| dc.subject.keywordPlus | UPS INVERTER | - |
| dc.subject.keywordPlus | ROBUST-CONTROL | - |
| dc.subject.keywordPlus | DESIGN | - |
| dc.subject.keywordPlus | CONVERTERS | - |
| dc.subject.keywordPlus | MICROGRIDS | - |
| dc.subject.keywordPlus | OPERATION | - |
| dc.subject.keywordPlus | PARALLEL | - |
| dc.subject.keywordPlus | FILTER | - |
| dc.subject.keywordAuthor | Adaptive control | - |
| dc.subject.keywordAuthor | distributed generation (DG) unit | - |
| dc.subject.keywordAuthor | disturbance observer | - |
| dc.subject.keywordAuthor | fuzzy control | - |
| dc.subject.keywordAuthor | standalone | - |
| dc.subject.keywordAuthor | voltage control | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.