Cited 0 time in
Evaluation of joint moment patterns of a wearable walking assistant robot: Experimental and simulation analyses
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kang, Ho Chul | - |
| dc.contributor.author | Lee, Ju Hwan | - |
| dc.contributor.author | Kim, Sung Min | - |
| dc.date.accessioned | 2024-08-08T07:01:01Z | - |
| dc.date.available | 2024-08-08T07:01:01Z | - |
| dc.date.issued | 2015 | - |
| dc.identifier.issn | 0959-2989 | - |
| dc.identifier.issn | 1878-3619 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/19254 | - |
| dc.description.abstract | This study analyzes the moment of human main joints (knee and hip) for developing a wearable walking assistant robot. Experiments were performed on two steps to analyze motions. Three healthy males with no neural and musculoskeletal disorders volunteered to participate in this study. In the step up test, the maximum moment was 0.98 +/- 0.05 Nm/kg for the knee and 0.52 +/- 0.04 Nm/kg for the hip. In the sit-to-stand test, the maximum moment was 0.88 +/- 0.06 Nm/kg for the knee and 0.44 +/- 0.04 Nm/kg for the hip. The moment of the hip was significantly higher than the knee. In addition, the motion analysis results were compared with proven validity and inverse dynamics analysis results. Experimental results showed that there was no significant difference in the absolute value or pattern. For the step up motion, after wearing Powered Gait Orthosis (PGO), the hip joint torque value (1.22 Nm/kg) was about 1.3 times greater than the knee joint torque value (0.96 Nm/kg). It indicates that the step up motion requires more power from the hip joint than the knee joint. Moreover, there was a significant torque value difference for before and after wearing the device. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IOS PRESS | - |
| dc.title | Evaluation of joint moment patterns of a wearable walking assistant robot: Experimental and simulation analyses | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.3233/BME-151363 | - |
| dc.identifier.wosid | 000361671800081 | - |
| dc.identifier.bibliographicCitation | BIO-MEDICAL MATERIALS AND ENGINEERING, v.26, pp S717 - S727 | - |
| dc.citation.title | BIO-MEDICAL MATERIALS AND ENGINEERING | - |
| dc.citation.volume | 26 | - |
| dc.citation.startPage | S717 | - |
| dc.citation.endPage | S727 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Materials Science | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
| dc.relation.journalWebOfScienceCategory | Materials Science, Biomaterials | - |
| dc.subject.keywordAuthor | Simulation | - |
| dc.subject.keywordAuthor | Powered Gait Orthosis (PGO) | - |
| dc.subject.keywordAuthor | torque | - |
| dc.subject.keywordAuthor | joint | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
