Cited 0 time in
Dual-Concentric Transducer with Phase Apodization for Wide Depth of Field of High-frequency Ultrasound Imaging
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jeong, Jong Seob | - |
| dc.contributor.author | Kim, Sung Min | - |
| dc.date.accessioned | 2024-08-08T06:01:43Z | - |
| dc.date.available | 2024-08-08T06:01:43Z | - |
| dc.date.issued | 2014-10-20 | - |
| dc.identifier.issn | 1948-5719 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/18819 | - |
| dc.description.abstract | In general, the length of the depth of field (DOF) is related to the quality of ultrasound B-mode image because the high-performance focusing can be accomplished within the DOF. Typically, under the fixed frequency and aperture size, the length of the DOF can be extended by increasing the focal depth while the intensity at focal point is reduced. This phenomenon is more severe at high frequency ultrasound imaging (HFUI) due to a short wavelength. In this study, we present a dual-concentric transducer combined with phase apodization resulting in the extended DOF maintaining intensity within the DOF range. The performance of the proposed method was numerically demonstrated by Field-II program based on 40 MHz point target and cyst imaging. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IEEE | - |
| dc.title | Dual-Concentric Transducer with Phase Apodization for Wide Depth of Field of High-frequency Ultrasound Imaging | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/ULTSYM.2014.0385 | - |
| dc.identifier.scopusid | 2-s2.0-84910089717 | - |
| dc.identifier.wosid | 000352792500384 | - |
| dc.identifier.bibliographicCitation | 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), pp 1555 - 1558 | - |
| dc.citation.title | 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | - |
| dc.citation.startPage | 1555 | - |
| dc.citation.endPage | 1558 | - |
| dc.type.docType | Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Acoustics | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Acoustics | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.subject.keywordPlus | ANNULAR ARMY TRANSDUCER | - |
| dc.subject.keywordPlus | PATTERN | - |
| dc.subject.keywordAuthor | Dual-concentric transducer | - |
| dc.subject.keywordAuthor | Depth of field | - |
| dc.subject.keywordAuthor | Phase-apodization | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
