Cited 109 time in
An Adaptive Voltage Control Strategy of Three-Phase Inverter for Stand-Alone Distributed Generation Systems
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Ton Duc Do | - |
| dc.contributor.author | Viet Quoc Leu | - |
| dc.contributor.author | Choi, Young-Sik | - |
| dc.contributor.author | Choi, Han Ho | - |
| dc.contributor.author | Jung, Jin-Woo | - |
| dc.date.accessioned | 2024-08-08T06:01:40Z | - |
| dc.date.available | 2024-08-08T06:01:40Z | - |
| dc.date.issued | 2013-12 | - |
| dc.identifier.issn | 0278-0046 | - |
| dc.identifier.issn | 1557-9948 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/18800 | - |
| dc.description.abstract | This paper proposes an adaptive control method of three-phase inverters for stand-alone distributed generation systems (DGSs). The proposed voltage controller includes two control terms: an adaptive compensating term and a stabilizing term. The adaptive compensating control term is constructed to avoid directly calculating the time derivatives of state variables. Meanwhile, the stabilizing control term is designed to asymptotically stabilize the error dynamics of the system. Also, a fourth-order optimal load current observer is proposed to reduce the number of current sensors and enhance the system reliability and cost effectiveness. The stability of the proposed voltage controller and the proposed load current observer is fully proven by using Lyapunov theory. The proposed control system can establish good voltage regulation such as fast dynamic response, small steady-state error, and low total harmonic distortion under sudden load change, unbalanced load, and nonlinear load. Finally, the validity of the proposed control strategy is verified through simulations and experiments on a prototype DGS test bed with a TMS320F28335 DSP. For a comparative study, the control scheme of feedback linearization for multi-input and multioutput is implemented, and its results are presented in this paper. | - |
| dc.format.extent | 13 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
| dc.title | An Adaptive Voltage Control Strategy of Three-Phase Inverter for Stand-Alone Distributed Generation Systems | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/TIE.2012.2230603 | - |
| dc.identifier.scopusid | 2-s2.0-84880314111 | - |
| dc.identifier.wosid | 000320946000028 | - |
| dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, v.60, no.12, pp 5660 - 5672 | - |
| dc.citation.title | IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS | - |
| dc.citation.volume | 60 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 5660 | - |
| dc.citation.endPage | 5672 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Automation & Control Systems | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Automation & Control Systems | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordPlus | STATIONARY REFERENCE FRAME | - |
| dc.subject.keywordPlus | SLIDING-MODE CONTROL | - |
| dc.subject.keywordPlus | ROBUST-CONTROL | - |
| dc.subject.keywordPlus | UPS | - |
| dc.subject.keywordPlus | DESIGN | - |
| dc.subject.keywordAuthor | Adaptive control | - |
| dc.subject.keywordAuthor | distributed generation (DG) system (DGS) | - |
| dc.subject.keywordAuthor | load current observer | - |
| dc.subject.keywordAuthor | stand-alone | - |
| dc.subject.keywordAuthor | three-phase inverter | - |
| dc.subject.keywordAuthor | voltage control | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.