Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Camera calibration and barrel undistortion for fisheye lens

Full metadata record
DC Field Value Language
dc.contributor.authorHeo, J.-Y.-
dc.contributor.authorLee, D.-W.-
dc.date.accessioned2024-08-08T06:01:35Z-
dc.date.available2024-08-08T06:01:35Z-
dc.date.issued2013-09-
dc.identifier.issn1975-8359-
dc.identifier.issn2287-4364-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/18770-
dc.description.abstractA lot of research about camera calibration and lens distortion for wide-angle lens has been made. Especially, calibration for fish-eye lens which has 180 degree FOV(field of view) or above is more tricky, so existing research employed a huge calibration pattern or even 3D pattern. And it is important that calibration parameters (such as distortion coefficients) are suitably initialized to get accurate calibration results. It can be achieved by using manufacturer information or lease-square method for relatively narrow FOV1(135, 150 degree) lens. In this paper, without any previous manufacturer information, camera calibration and barrel undistortion for fish-eye lens with over 180 degree FOV are achieved by only using one calibration pattern image. We applied QR decomposition for initialization and Regularization for optimization. With the result of experiment, we verified that our algorithm can achieve camera calibration and image undistortion successfully.-
dc.format.extent6-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한전기학회-
dc.titleCamera calibration and barrel undistortion for fisheye lens-
dc.title.alternativeCamera Calibration and Barrel Undistortion for Fisheye Lens-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.5370/KIEE.2013.62.9.1270-
dc.identifier.scopusid2-s2.0-84886940996-
dc.identifier.bibliographicCitationTransactions of the Korean Institute of Electrical Engineers, v.62, no.9, pp 1270 - 1275-
dc.citation.titleTransactions of the Korean Institute of Electrical Engineers-
dc.citation.volume62-
dc.citation.number9-
dc.citation.startPage1270-
dc.citation.endPage1275-
dc.type.docTypeArticle-
dc.identifier.kciidART001801068-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorBarrel undistortion-
dc.subject.keywordAuthorCamera calibration-
dc.subject.keywordAuthorFish-eye lens-
dc.subject.keywordAuthorQr decoposition-
dc.subject.keywordAuthorRegularization-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Electronics and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE