Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가open accessAccuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation

Other Titles
Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation
Authors
심수영유호석김한별정재훈이상준김성민박광석
Issue Date
Oct-2014
Publisher
대한의용생체공학회
Keywords
Body temperature; Noninvasive thermometer; Finite element model
Citation
의공학회지, v.35, no.5, pp 160 - 168
Pages
9
Indexed
KCI
Journal Title
의공학회지
Volume
35
Number
5
Start Page
160
End Page
168
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/18551
DOI
10.9718/JBER.2014.35.5.160
ISSN
1229-0807
2288-9396
Abstract
Continuous body temperature monitoring is useful and essential in diverse medical procedures such asinfection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, andgynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-termbody temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which cannoninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed asK-value should be obtained to estimate body temperature with the thermometer and it can be different under variousmeasurement environments. Although the device was proven to be useful through preliminary simulation test andsmall group of human study, the experimental environment was restrictive in our previous approach. In this study,a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometerunder various measurement environments. In addition, K-value estimation equation was developed by analyzing theinfluence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusionrate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deepbody thermometer based on computer simulation was very high (RMSE < 0.003oC) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurateresults (RMSE < 0.3oC) except for one case. Although the K-value estimation technology should be improved formore accurate body temperature estimation, the results of finite element simulation showed that bi-medium deepbody thermometer could accurately measure various tissue temperatures under diverse environments.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Science and Biotechnology > Department of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sung Min photo

Kim, Sung Min
College of Life Science and Biotechnology (Department of Biomedical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE