Cited 0 time in
속목정맥 중심정맥관 삽입과 합병증의 확인을 위한 초음파 지침의 유용성: Sonographic Assessment of the Venous Excavation (SAVE) Protocol
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 조민수 | - |
| dc.contributor.author | 도한호 | - |
| dc.contributor.author | 서준석 | - |
| dc.contributor.author | 이상헌 | - |
| dc.contributor.author | 김희영 | - |
| dc.contributor.author | 하영록 | - |
| dc.date.accessioned | 2024-08-08T05:01:47Z | - |
| dc.date.available | 2024-08-08T05:01:47Z | - |
| dc.date.issued | 2014-06 | - |
| dc.identifier.issn | 1226-4334 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/18544 | - |
| dc.description.abstract | Purpose: Central venous catheterization (CVC) playsimportant roles in treatment of critically ill patients. Althoughuse of ultrasound has led to a decrease in CVC related complications,adverse events still occur. Therefore, we usuallycheck the chest x-ray for confirmation. The purpose of thisstudy was to evaluate the usefulness of point of care ultrasoundduring catheterization of the internal jugular vein (IJV). Methods: The authors conducted a prospective study ofemergency department (ED) patients undergoing CVC viaIJV. Among the enrolled patients, 97 underwent SAVE,which consisted of 1) pre-CVC lung ultrasound, 2) ultrasoundguided puncture of central vein, 3) sonographicdetection of the guide wire before dilation, and 4) post-CVClung ultrasonography. The primary outcome was the successrate of each stage. The secondary outcome was anestimated time of the SAVE exam. The entire process ofpatients’ care was recorded by video for the purpose of timeanalysis. Physicians described anatomical site, reason forcatheterization, and acute mechanical complications. Results: In all subjects, the guide wire was visible withinthe lumen of the IJV. Median access time, from insertion todetection of the guide wire in IJV via ultrasound, was 20seconds. After the CVC was inserted, post-CVC lung ultrasonographywas completed within a median time of 68 seconds. Identification of the chest x-ray image took more than5 minutes. Acute mechanical complications - whichoccurred in three patients - were detected immediately bySAVE. Conclusion: SAVE may provide greater safety during CVCby detection of CVC related complication more properly,without delay. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한응급의학회 | - |
| dc.title | 속목정맥 중심정맥관 삽입과 합병증의 확인을 위한 초음파 지침의 유용성: Sonographic Assessment of the Venous Excavation (SAVE) Protocol | - |
| dc.title.alternative | A Point of Care Ultrasound During Catheterization of Internal Jugular Vein; Sonographic Assessment of the Venous Excavation (SAVE) Protocol | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 대한응급의학회지, v.25, no.3, pp 291 - 298 | - |
| dc.citation.title | 대한응급의학회지 | - |
| dc.citation.volume | 25 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 291 | - |
| dc.citation.endPage | 298 | - |
| dc.identifier.kciid | ART001888835 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Ultrasonography | - |
| dc.subject.keywordAuthor | Central Venous Catheterization | - |
| dc.subject.keywordAuthor | Patient Safety | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
