Cited 9 time in
The effect of head tilt on keratometric measurement using the IOLMaster
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, C. Y. | - |
| dc.contributor.author | Do, J. R. | - |
| dc.contributor.author | Kim, S. H. | - |
| dc.contributor.author | Lim, C-Y | - |
| dc.contributor.author | Chuck, R. S. | - |
| dc.date.accessioned | 2024-08-08T05:01:28Z | - |
| dc.date.available | 2024-08-08T05:01:28Z | - |
| dc.date.issued | 2013-12 | - |
| dc.identifier.issn | 0950-222X | - |
| dc.identifier.issn | 1476-5454 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/18427 | - |
| dc.description.abstract | Purpose To investigate the effect of head tilt on keratometric measurement using the IOLMaster. Methods Twenty-seven right eyes of 27 volunteers were examined using a manual keratometer (MK), automated keratometer (AK), and an IOLMaster. MK and AK measurements were performed in the upright head position, whereas IOLMaster measurements were performed in five different head positions (upright, 5 degrees or 15 degrees clockwise head tilt, and 5 degrees or 15 degrees counter-clockwise head tilt). The repeatability of IOLMaster was compared with MK and AK. The keratometric measurements (mean keratometric power, magnitude of astigmatism, and steep meridian) in different head positions were compared. Results The IOLMaster showed good repeatability of keratometric measurement comparable to MK or AK. 15 degrees and 5 degrees clockwise head tilt resulted in 12.09+/-9.51 (mean+/-SD) (P<0.001 vs upright) and 5.51+/-5.97 (mean+/-SD) degrees (P<0.001) of clockwise rotation of steep meridian, respectively. 15 degrees and 5 degrees counter-clockwise head tilt resulted in 12.49+/-7.07 (mean+/-SD) (P<0.001) and 6.08+/-5.09 (mean+/-SD) degrees (P<0.001) of counter-clockwise rotation of steep meridian, respectively. Conclusions The patient's head tilt (5 degrees or 15 degrees, clockwise or counter-clockwise) significantly changed the steep meridian of astigmatism measured using IOLMaster and the steep meridian generally shifted to the direction of head tilt. The importance of maintaining the upright head posture during IOLMaster measurement is demonstrated. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | NATURE PUBLISHING GROUP | - |
| dc.title | The effect of head tilt on keratometric measurement using the IOLMaster | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1038/eye.2013.209 | - |
| dc.identifier.scopusid | 2-s2.0-84890498609 | - |
| dc.identifier.wosid | 000328602000012 | - |
| dc.identifier.bibliographicCitation | EYE, v.27, no.12, pp 1411 - 1417 | - |
| dc.citation.title | EYE | - |
| dc.citation.volume | 27 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 1411 | - |
| dc.citation.endPage | 1417 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Ophthalmology | - |
| dc.relation.journalWebOfScienceCategory | Ophthalmology | - |
| dc.subject.keywordPlus | PARTIAL COHERENCE INTERFEROMETRY | - |
| dc.subject.keywordPlus | INTRAOCULAR-LENS IMPLANTATION | - |
| dc.subject.keywordPlus | REFRACTIVE OUTCOMES | - |
| dc.subject.keywordPlus | OCULAR CYCLOTORSION | - |
| dc.subject.keywordPlus | CATARACT | - |
| dc.subject.keywordPlus | BIOMETRY | - |
| dc.subject.keywordAuthor | astigmatism | - |
| dc.subject.keywordAuthor | keratometry | - |
| dc.subject.keywordAuthor | head tilt | - |
| dc.subject.keywordAuthor | cyclotorsion | - |
| dc.subject.keywordAuthor | IOLMaster | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.