Detailed Information

Cited 8 time in webofscience Cited 9 time in scopus
Metadata Downloads

Heat Generation and Efficiency of a New Modified Phaco Tip and Sleeve

Full metadata record
DC Field Value Language
dc.contributor.authorYoo, Aeri-
dc.contributor.authorNam, Ki Yeun-
dc.contributor.authorTchah, Hungwon-
dc.contributor.authorKim, Myoung Joon-
dc.date.accessioned2024-08-08T04:31:44Z-
dc.date.available2024-08-08T04:31:44Z-
dc.date.issued2016-08-03-
dc.identifier.issn1932-6203-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/18094-
dc.description.abstractPurpose To compare a modified phacoemulsification tip with the established micro tip, in terms of temperature at the corneal wound, efficiency, and chatter events, using the Centurion (R) Vision system. Methods Eighty porcine eyes were randomized into 4 groups: 1) sleeveless conventional 45D Mini-Flared ABS (R) Kelman tip (1.1-mm incision); 2) sleeveless new modified 45D ABS (R) INTREPID (R) balanced tip(1.1-mm incision); 3) Kelman tip with own sleeve (2.2-mm incision); 4) Balanced tip with modified 4-rib sleeve (2.2-mm incision). Measurements were taken with 2 settings: longitudinal(power 40% and 70%) and torsional mode (power 40% and 100%). Peak temperatures were measured 0, 10, 30, and 60 seconds after continuous ultrasound power. For the efficiency test, porcine lens nuclei were formalin soaked and cut into 2.0 mm(3) cubes. Efficiency and chatter were examined. Results In all longitudinal settings, the sleeveless groups(1 and 2) showed lower temperatures than the sleeved groups(3 and 4) (P = 0.003). In 100% torsional mode, groups 3 and 4 produced significantly different temperatures(37.13 +/- 1.44 and 35.14 +/- 0.54, respectively; P = 0.007). The efficiency, in a 100% power torsional setting, was 13.52 +/- 2.60 sec for group 4, and 44.45 +/- 14.75 sec for group 3 (P<0.001). Conclusions The two different bare tips show no significant differences in thermogenesis. However, the balanced tip with sleeve produces lower temperaturesat100% torsional power and better efficiency than the Kelman tip.-
dc.language영어-
dc.language.isoENG-
dc.publisherPUBLIC LIBRARY SCIENCE-
dc.titleHeat Generation and Efficiency of a New Modified Phaco Tip and Sleeve-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1371/journal.pone.0159049-
dc.identifier.scopusid2-s2.0-84983613445-
dc.identifier.wosid000381367800016-
dc.identifier.bibliographicCitationPLOS ONE, v.11, no.8-
dc.citation.titlePLOS ONE-
dc.citation.volume11-
dc.citation.number8-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusULTRASOUND MODALITIES-
dc.subject.keywordPlusCATARACT-SURGERY-
dc.subject.keywordPlusPHACOEMULSIFICATION-
dc.subject.keywordPlusMICROINCISION-
dc.subject.keywordPlusCHATTER-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Nam, Ki Yeun photo

Nam, Ki Yeun
Graduate School (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE