Cited 18 time in
Compensation Method of Natural Head Movement for Gaze Tracking System Using an Ultrasonic Sensor for Distance Measurement
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jung, Dongwook | - |
| dc.contributor.author | Lee, Jong Man | - |
| dc.contributor.author | Gwon, Su Yeong | - |
| dc.contributor.author | Pan, Weiyuan | - |
| dc.contributor.author | Lee, Hyeon Chang | - |
| dc.contributor.author | Park, Kang Ryoung | - |
| dc.contributor.author | Kim, Hyun-Cheol | - |
| dc.date.accessioned | 2024-08-08T04:31:42Z | - |
| dc.date.available | 2024-08-08T04:31:42Z | - |
| dc.date.issued | 2016-01 | - |
| dc.identifier.issn | 1424-8220 | - |
| dc.identifier.issn | 1424-3210 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/18078 | - |
| dc.description.abstract | Most gaze tracking systems are based on the pupil center corneal reflection (PCCR) method using near infrared (NIR) illuminators. One advantage of the PCCR method is the high accuracy it achieves in gaze tracking because it compensates for the pupil center position based on the relative position of corneal specular reflection (SR). However, the PCCR method only works for user head movements within a limited range, and its performance is degraded by the natural movement of the user's head. To overcome this problem, we propose a gaze tracking method using an ultrasonic sensor that is robust to the natural head movement of users. Experimental results demonstrate that with our compensation method the gaze tracking system is more robust to natural head movements compared to other systems without our method and commercial systems. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | MDPI | - |
| dc.title | Compensation Method of Natural Head Movement for Gaze Tracking System Using an Ultrasonic Sensor for Distance Measurement | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.3390/s16010110 | - |
| dc.identifier.scopusid | 2-s2.0-84954318904 | - |
| dc.identifier.wosid | 000370679800053 | - |
| dc.identifier.bibliographicCitation | SENSORS, v.16, no.1 | - |
| dc.citation.title | SENSORS | - |
| dc.citation.volume | 16 | - |
| dc.citation.number | 1 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordPlus | EYE | - |
| dc.subject.keywordAuthor | gaze tracking system | - |
| dc.subject.keywordAuthor | compensation of head movements | - |
| dc.subject.keywordAuthor | ultrasonic sensor | - |
| dc.subject.keywordAuthor | natural head movement | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
