Modified Tension Band Wiring Combined with Anti-Gliding Loop Augmentation Technique for the Treatment of Comminuted Patellar Fracture: Technical Note and Report of Early Results- Technical Note
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이한준 | - |
| dc.contributor.author | 양재준 | - |
| dc.contributor.author | 정호중 | - |
| dc.contributor.author | 정형석 | - |
| dc.date.accessioned | 2024-08-08T04:01:05Z | - |
| dc.date.available | 2024-08-08T04:01:05Z | - |
| dc.date.issued | 2013-10 | - |
| dc.identifier.issn | 1225-1682 | - |
| dc.identifier.issn | 2287-9293 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/17482 | - |
| dc.description.abstract | In order to investigate the feasibility of a modified tension band combined with anti-gliding loop augmentation technique for the treatment of comminuted patellar fracture, 21 patients with comminuted patellar fracture were enrolled in this study. After the modified tension band wiring of patellar fracture, a cerclage wire was passed around the patella. Anti-gliding loops were made on the bending sites of Kirshner-wires. A knot was tied using both ends of the anti-gliding loops, and the cerclage wire was tightened using proximal knots. Bone union was achieved at 4.5±1.5 months postoperatively without nonunion. The Lysholm score was 87.1±2.8, and the range of motion of the knee was 2.1o±3.4o to 132.2o±6.5o at the last follow-up. The modified tension band combined with anti-gliding loop augmentation technique might be considered an alter-native modification of modified tension band wiring for the treatment of comminuted patellar fracture. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한골절학회 | - |
| dc.title | Modified Tension Band Wiring Combined with Anti-Gliding Loop Augmentation Technique for the Treatment of Comminuted Patellar Fracture: Technical Note and Report of Early Results- Technical Note | - |
| dc.title.alternative | Modified Tension Band Wiring Combined with Anti-Gliding Loop Augmentation Technique for the Treatment of Comminuted Patellar Fracture: Technical Note and Report of Early Results- Technical Note | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 대한골절학회지, v.26, no.4, pp 321 - 326 | - |
| dc.citation.title | 대한골절학회지 | - |
| dc.citation.volume | 26 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 321 | - |
| dc.citation.endPage | 326 | - |
| dc.identifier.kciid | ART001812381 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Patellar fracture | - |
| dc.subject.keywordAuthor | Comminuted fractures | - |
| dc.subject.keywordAuthor | Modified tension band | - |
| dc.subject.keywordAuthor | Cerclage wire | - |
| dc.subject.keywordAuthor | Anti-gliding loop | - |
| dc.subject.keywordAuthor | 슬개골 골절 | - |
| dc.subject.keywordAuthor | 분쇄 골절 | - |
| dc.subject.keywordAuthor | 변형 긴장대 강선 | - |
| dc.subject.keywordAuthor | Cerclage wire | - |
| dc.subject.keywordAuthor | Anti-gliding loop | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.