Cited 35 time in
Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Yoon, Sangpil | - |
| dc.contributor.author | Williams, Jay | - |
| dc.contributor.author | Kang, Bong Jin | - |
| dc.contributor.author | Yoon, Changhan | - |
| dc.contributor.author | Cabrera-Munoz, Nestor | - |
| dc.contributor.author | Jeong, Jong Seob | - |
| dc.contributor.author | Lee, Sang Goo | - |
| dc.contributor.author | Shung, K. Kirk | - |
| dc.contributor.author | Kim, Hyung Ham | - |
| dc.date.accessioned | 2024-08-08T03:31:11Z | - |
| dc.date.available | 2024-08-08T03:31:11Z | - |
| dc.date.issued | 2015-06-01 | - |
| dc.identifier.issn | 0924-4247 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/17135 | - |
| dc.description.abstract | A transducer with an angled and focused aperture for intravascular ultrasound imaging has been developed. The acoustic stack for the angled-focused transducer was made of PMN-PT single crystal with one matching layer, one protective coating layer, and a highly damped backing layer. It was then press-focused to a desired focal length and inserted into a thin needle housing with an angled tip. A transducer with an angled and unfocused aperture was also made, following the same fabrication procedure, to compare the performance of the two transducers. The focused and unfocused transducers were tested to measure their center frequencies, bandwidths, and spatial resolutions. Lateral resolution of the angled-focused transducer (AFT) improved more than two times compared to that of the angled-unfocused transducer (AUT). A tissue-mimicking phantom in water and a rabbit aorta tissue sample in rabbit blood were scanned using AFT and AUT. Imaging with AFT offered improved contrast, over imaging with AUT, of the tissue-mimicking phantom and the rabbit aorta tissue sample by 23 dB and 8 dB, respectively. The results show that AFT has strong potential to provide morphological and pathological information of coronary arteries with high resolution and high contrast. (C) 2015 Elsevier B.V. All rights reserved. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | ELSEVIER SCIENCE SA | - |
| dc.title | Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.1016/j.sna.2015.02.037 | - |
| dc.identifier.scopusid | 2-s2.0-84925342514 | - |
| dc.identifier.wosid | 000355043800003 | - |
| dc.identifier.bibliographicCitation | SENSORS AND ACTUATORS A-PHYSICAL, v.228, pp 16 - 22 | - |
| dc.citation.title | SENSORS AND ACTUATORS A-PHYSICAL | - |
| dc.citation.volume | 228 | - |
| dc.citation.startPage | 16 | - |
| dc.citation.endPage | 22 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordPlus | OPTICAL COHERENCE TOMOGRAPHY | - |
| dc.subject.keywordPlus | TASK-FORCE | - |
| dc.subject.keywordPlus | ANGIOGRAPHY | - |
| dc.subject.keywordPlus | ATHEROSCLEROSIS | - |
| dc.subject.keywordPlus | MORPHOLOGY | - |
| dc.subject.keywordPlus | ACCURACY | - |
| dc.subject.keywordPlus | SOCIETY | - |
| dc.subject.keywordPlus | DISEASE | - |
| dc.subject.keywordPlus | IVUS | - |
| dc.subject.keywordAuthor | Intravascular ultrasound (IVUS) imaging | - |
| dc.subject.keywordAuthor | Angled-focused transducer | - |
| dc.subject.keywordAuthor | High frequency transducer | - |
| dc.subject.keywordAuthor | Contrast | - |
| dc.subject.keywordAuthor | Coronary stenosis evaluation | - |
| dc.subject.keywordAuthor | Rabbit aorta | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
