Detailed Information

Cited 14 time in webofscience Cited 16 time in scopus
Metadata Downloads

Segmentation of the lumen and media-adventitial borders in intravascular ultrasound images using a geometric deformable model

Authors
Lee, Ju HwanHwang, Yoo NaKim, Ga YoungMin, Kim Sung
Issue Date
Oct-2018
Publisher
INST ENGINEERING TECHNOLOGY-IET
Keywords
medical image processing; image segmentation; biomedical ultrasonics; catheters; image denoising; evolutionary computation; set theory; media-adventitial borders; lumen segmentation; intravascular ultrasound images; geometric deformable model; intima segmentation; sequential intravascular ultrasound images; sequential IVUS image frames; human coronary arteries; catheters; vessel border estimation; border initialisation; edge preservation; noise reduction; dead zone preservation; local binary pattern-based mask initialisation; modified distance regularised level set evolution model; correlation coefficients; vessel perimeter; maximum vessel diameter; maximum lumen diameter; linear regression analysis; frequency 20 MHz; frequency 45 MHz
Citation
IET IMAGE PROCESSING, v.12, no.10, pp 1881 - 1891
Pages
11
Indexed
SCI
SCIE
SCOPUS
Journal Title
IET IMAGE PROCESSING
Volume
12
Number
10
Start Page
1881
End Page
1891
URI
https://scholarworks.dongguk.edu/handle/sw.dongguk/17103
DOI
10.1049/iet-ipr.2017.1143
ISSN
1751-9659
1751-9667
Abstract
This study presents a geometric deformable model-based segmentation approach to segmentation of the intima and media-adventitial (MA) borders in sequential intravascular ultrasound (IVUS) images. The initial estimation of the vessel borders was done manually only for the first frame of each sequence. After the border initialisation, pre-processing including edge preservation, noise reduction, and dead zone preservation was successively performed on each IVUS frame. To improve segmentation performance, the image masks were determined preliminarily by local binary pattern-based mask initialisation. Then, the inner and outer borders were approximated using a modified distance regularised level set evolution model. The results showed superior performance of the suggested approach for estimating intima and MA layers from the IVUS images. The corresponding correlation coefficients of area, vessel perimeter, maximum vessel diameter, and maximum lumen diameter were r=0.782, r=0.716, r=0.956, and r=0.874 for the 20MHz images, respectively, and r=0.990, r=0.995, r=0.989, and r=0.996 for the 45MHz images, respectively. In addition, linear regression analysis indicated that the manual segmentation had significantly high similarity at r>0.967 and r>0.993 for 20 and 45MHz images, respectively.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Life Science and Biotechnology > Department of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sung Min photo

Kim, Sung Min
College of Life Science and Biotechnology (Department of Biomedical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE