Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of the endotracheal tube intracuff pressure with cylindrical and tapered cuffs during nitrous oxide exposure: a randomized single-blinded clinical study

Full metadata record
DC Field Value Language
dc.contributor.author박하연-
dc.contributor.author김대환-
dc.contributor.author인준용-
dc.date.accessioned2024-08-08T03:30:41Z-
dc.date.available2024-08-08T03:30:41Z-
dc.date.issued2017-07-
dc.identifier.issn1975-5171-
dc.identifier.issn2383-7977-
dc.identifier.urihttps://scholarworks.dongguk.edu/handle/sw.dongguk/16934-
dc.description.abstractBackground: Tracheal complications caused by excessive mucosal pressure from an inflated endotracheal tube are major concerns during anesthesia; hence, an intracuff pressure of 20–30 cmH2O is recommended as a clinically acceptable intracuff pressure. Diffusion of nitrous oxide (N2O) into the endotracheal tube cuff increases the intracuff pressure, which may also be influenced by the cuff shape. Therefore, we investigated whether the intracuff pressure of a tapered cuff was different from that of a cylindrical cuff in patients undergoing general anesthesia using 60% N2O. Methods: Twenty-six patients who underwent general anesthesia using 60% N2O in supine position were randomly allocated to the cylindrical cuff group (Group C) or tapered cuff group (Group T). The baseline intracuff pressure was set at 20 cmH2O, and measured every 10 minutes for 60 minutes. Results: The primary outcome was the intracuff pressure at 60 minutes after N2O exposure, which was 40 cmH2O in Group C (95% CI 36–44) and 40 cmH2O (95% CI 35–45) in Group T (P = 0.895). The lower confidence limit of the intracuff pressures in both groups exceeded 30 cmH2O at 60 minutes of N2O exposure, which is the upper limit for clinically acceptable intracuff pressure (20–30 cmH2O). Conclusions: There was no significant difference in the intracuff pressures between cylindrical and tapered cuffs. Continuous or frequent monitoring is recommended regardless of the duration of the 60% N2O exposure because the intracuff pressure can exceed 30 cmH2O within an hour.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisher대한마취통증의학회-
dc.titleComparison of the endotracheal tube intracuff pressure with cylindrical and tapered cuffs during nitrous oxide exposure: a randomized single-blinded clinical study-
dc.title.alternativeComparison of the endotracheal tube intracuff pressure with cylindrical and tapered cuffs during nitrous oxide exposure: a randomized single-blinded clinical study-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitationAnesthesia and Pain Medicine, v.12, no.3, pp 275 - 280-
dc.citation.titleAnesthesia and Pain Medicine-
dc.citation.volume12-
dc.citation.number3-
dc.citation.startPage275-
dc.citation.endPage280-
dc.identifier.kciidART002247494-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorAirway management-
dc.subject.keywordAuthorIntratracheal intubation-
dc.subject.keywordAuthorNitrous oxide.-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher In, Jun Yong photo

In, Jun Yong
Graduate School (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE