Cited 0 time in
빌딩간 연결을 통한 복합제어시스템의 최적설계
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박관순 | - |
| dc.contributor.author | 옥승용 | - |
| dc.date.accessioned | 2024-08-08T03:01:45Z | - |
| dc.date.available | 2024-08-08T03:01:45Z | - |
| dc.date.issued | 2017-12 | - |
| dc.identifier.issn | 1738-3803 | - |
| dc.identifier.issn | 2383-9953 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/16782 | - |
| dc.description.abstract | This study deals with the optimal design of a hybrid control system composed of a combination of active control system and passive control system for effective seismic performance improvement of two adjacent structures. The proposed hybrid control system adopts a configuration of installing an active control device in one building and connecting two adjacent structures with a passive control device so that the one-side active control force can be bi-directionally applied to both buildings through the passive connecting devices. In order to derive the optimal performance of the proposed system, the design parameters of the passive and active control systems were searched using the genetic algorithm. Numerical simulations of 10-story and 8-story buildings have been performed to verify the effectiveness of the proposed technique. For the purpose of comparison, the conventional independent control system with two identical active control systems being installed separately for each structure was also optimally designed and its seismic response has been evaluated as well. From the comparative results of the two control systems, it is demonstrated that the proposed hybrid control system requires larger control force for its one-side active control device than the conventional independent control system does for each of both-side active devices, but quite less than the total control force required for both-side devices of the independent control system, while maintaining similar seismic performance. Therefore, the proposed system is more economical and reliable than the conventional independent control system with two identical active devices. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국안전학회 | - |
| dc.title | 빌딩간 연결을 통한 복합제어시스템의 최적설계 | - |
| dc.title.alternative | Optimal Design of Hybrid Control System through Inter-Building Connection | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국안전학회지, v.32, no.6, pp 81 - 88 | - |
| dc.citation.title | 한국안전학회지 | - |
| dc.citation.volume | 32 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 81 | - |
| dc.citation.endPage | 88 | - |
| dc.identifier.kciid | ART002304428 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | hybrid control system | - |
| dc.subject.keywordAuthor | optimal control design | - |
| dc.subject.keywordAuthor | two adjacent structures | - |
| dc.subject.keywordAuthor | active tuned mass damper | - |
| dc.subject.keywordAuthor | passive stiffness connection | - |
| dc.subject.keywordAuthor | passive damper connection | - |
| dc.subject.keywordAuthor | genetic algorithm | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.