Cited 0 time in
다중 능동형 동조질량감쇠기가 설치된 고층빌딩의 내진성능 평가
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박관순 | - |
| dc.contributor.author | 옥승용 | - |
| dc.date.accessioned | 2024-08-08T03:01:44Z | - |
| dc.date.available | 2024-08-08T03:01:44Z | - |
| dc.date.issued | 2017-12 | - |
| dc.identifier.issn | 1738-3803 | - |
| dc.identifier.issn | 2383-9953 | - |
| dc.identifier.uri | https://scholarworks.dongguk.edu/handle/sw.dongguk/16770 | - |
| dc.description.abstract | The tuned mass damper (TMD) system was first proposed as an efficient vibration control method for high-rise buildings, and multiple TMD (MTMD) system was then proposed for the purpose of improving the robust performance. Thereafter, the active TMD (ATMD) is proposed to improve the vibration control performance over the TMD and MTMD systems. However, this system may experience an system-instability problem in case of the actuator malfunction. In order to overcome such limitations of actuator malfunction causing the instability of the structural system, in this study, we investigate the feasibility of the multiple ATMD (MATMD) system that facilitates both advantages of the MTMD and ATMD. Numerical example demonstrates that, when the proposed system is designed to have the same capacity as the ATMD, it shows a similar control performance to the ATMD, but also has very good adaptive control performance against the emergency situations such as actuator failures. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국안전학회 | - |
| dc.title | 다중 능동형 동조질량감쇠기가 설치된 고층빌딩의 내진성능 평가 | - |
| dc.title.alternative | Seismic Performance Assessment of High-Rise Building installed with Multiple Active Tuned Mass Dampers | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국안전학회지, v.32, no.6, pp 89 - 97 | - |
| dc.citation.title | 한국안전학회지 | - |
| dc.citation.volume | 32 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 89 | - |
| dc.citation.endPage | 97 | - |
| dc.identifier.kciid | ART002304431 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | multiple active tuned mass damper | - |
| dc.subject.keywordAuthor | high-rise building | - |
| dc.subject.keywordAuthor | adaptive control performance | - |
| dc.subject.keywordAuthor | actuator failure | - |
| dc.subject.keywordAuthor | seismic performance | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
30, Pildong-ro 1-gil, Jung-gu, Seoul, 04620, Republic of Korea+82-2-2260-3114
Copyright(c) 2023 DONGGUK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.